Brand | Model | Fault | Detailed Problem | Solution | By |
---|---|---|---|---|---|
JVC | AV-S250EKT | Set dead. faint whistling noise on switch on. no standby led | Replaced str1006, no dfference. line o/p transistor ok. 36 volt zener, d614 found to be short. this zener is on the secondary of xformer, t601. this short causes the 12 v start up supply cct, which includes str1006 not to come on | ||
JVC | AV-S250EKT | Set dead. faint whistling noise on switch on. no standby led | Replaced str1006, no dfference. line o/p transistor ok. 36 volt zener, d614 found to be short. this zener is on the secondary of xformer, t601. this short causes the 12 v start up supply cct, which includes str1006 not to come on |