Jvc AV-S250EKT Repair Guide: Common Issues and Fixes

Brand Model Fault Detailed Problem Solution By
JVC AV-S250EKT
Set dead. faint whistling noise on switch on. no standby ledReplaced str1006, no dfference. line o/p transistor ok. 36 volt zener, d614 found to be short. this zener is on the secondary of xformer, t601. this short causes the 12 v start up supply cct, which includes str1006 not to come on
JVC AV-S250EKT
Set dead. faint whistling noise on switch on. no standby ledReplaced str1006, no dfference. line o/p transistor ok. 36 volt zener, d614 found to be short. this zener is on the secondary of xformer, t601. this short causes the 12 v start up supply cct, which includes str1006 not to come on