Mitsubishi CT-21M1 EPM Repair Guide: Common Issues and Fixes

Brand Model Fault Detailed Problem Solution By
MITSUBISHICT-21M1 EPM
I didn’t memorize the channels!After checking the r-955 which was good, the negative voltage of 30 volts was still low, I then verified that the lack of capacity of the c-962 was at the root of the problem, I just had to replace it! these components are located at the power supply power supply next to the transformer.J.J.
MITSUBISHICT-21M1 EPM
I didn’t memorize the channels!After checking the r-955 which was good, the negative voltage of 30 volts was still low, I then verified that the lack of capacity of the c-962 was at the root of the problem, I just had to replace it! these components are located at the power supply power supply next to the transformer.J.J.