Search: Samsung
Results: 3756

Samsung Repair Guide: Common Issues and Fixes

Brand Model Fault Detailed Problem Solution By
SAMSUNGCI5913 & CI6813
If ht smoother c560 2µ 250v has failed (on crt base)Change c410 or c401 from 220µ 100v to 47µ 250v. connect -ve pin to chassis. change c416 from 2µ2 250v to 47µ 250v. if r415 0r27 ½w is fitted check for o/c - if so replace - official samsung mod
SAMSUNGCI5913 CI6813 U U88
Dark pictureCheck c416 ( 155v smoothing ) replace with 47mfd 250v
SAMSUNGCI591
Dark pic with ringingCaps in 175v supply to rgb low - c560 2µ2 400v on crt base & c410 220µ 200v on main pcb
SAMSUNGCI541ZG
Will not lock into channels - no sound.B5 rail @ 3.4v infra red rx leaky ( unplug pa01 - 5 rail restored )
SAMSUNGCI541ZG
Stuck in standby.Q402 ( 2sd1650 ) s/c.
SAMSUNGCI541ZG
Sound crackling & cutting out.R618 ( 5.6k ) near audio ic.
SAMSUNGCI541ZG
Psu & lopt pulsing - no sound.B5 rail @ 3.4v infra red rx leaky ( unplug pa01 - 5 rail restored )
SAMSUNGCI541ZG
No sound - set tripping - black bars on pic.B5 rail @ 3.4v infra red rx leaky ( unplug pa01 - 5 rail restored )
SAMSUNGCI541ZG
No red may be int.Sprinkle q556 ( crt pcb )
SAMSUNGCI541ZG
Int shut downInvisible dry joints at chopper trfmr
SAMSUNGCI541ZG
Frame collapse.R412 ( 1r 1/2w fusible ) o/c.
SAMSUNGCI541ZG
Dead with relay clickingC411 100pf 2kv s/c in lop stage
SAMSUNGCI541ZG
Dead with relay clickingC411 100pf 2kv s/c in lop stage
SAMSUNGCI537V P55
Set comes out of stby but returns in 10secsD912 oc no line osc start up supply
SAMSUNGCI537V P55
Replacement tuner mod with ecc-2885ple ( s ) two pinsOn left and reading l-r - bu - vt - bh - agc - bl - aft - old unit = 34519-990-040 ecu 5883ple , new = 34519-9
SAMSUNGCI537V P55
Dead - psu works but no standby dash.Xf001 ( 12mhz ) xtal , d912.
SAMSUNGCI537V P55
Contrast low & unadjustable.12k res on front pcb.
SAMSUNGCI537V P55
Blank screen.Ic tda2653a due to lack of heatsink compound.
SAMSUNGCI537V P55
Blank raster - works on video inputTuner unit us
SAMSUNGCI537V
Stuck in av modeReplace tuner where switching is carried out