Sony Repair Guide: Common Issues and Fixes

Brand Model Fault Detailed Problem Solution By
SONYSTRV55
Wire numbers are reversedIncorrect wire number. numbers #1 and #3 reversed.
SONYSTRV35
Defective outputsThe npn output transistor opened on one channel of each of these receivers. no other problems found.
SONYSTRV2
P/n for glassCases of concealed damage to front glass on these models havebeen reported. present solution is to replace entire front panel assemblybut it is costly. -hq comments: a similar situation developed on the str-4800sd, -5800sd,-6800sd models 3 years ago.
SONYSTR7065
Protection transistors reversedBurned main amplifier board was replaced (x-482-232-50).amplifier clipped at 1 watt out.
SONYSTR212
Defective ic20, 301, q301, 302No am or fm - ic201 voltages incorrect, q301 collector read 11volts. replacement of individual ic, would knock the other chip out.
SONYSTC7000
Adjustment neededThe maximum deflection on tuner input meter did not correspondto center channel on tuning meter. adjustment of fm discriminator and fmif was unsuccessful.
SONYSQA2030
Defective q701Noise in back channel outputs. -hq comments: replaced regulator transistor q701, 2sc1124.
SONYPSX70
Weak motorTone arm would not complete return and play cycle wouldstop widway most times.
SONYPSX40
Defective mghTurntable speed erratic. maximum output from mgh was 15-20mvp-p. even slight readjustment of the head caused it to scrape theplatter.
SONYPSX30
Loose lead on c101Frequent slowing down of motor. found one lead of c101loose.
SONYPSX30
Defective detection leverScraping noise. cause: detection lever had been jammed underprotrusion on bottom of cam gear in shipping and was permanently warped.this was touching the top of the magnet ass'y on the motor shaft.
SONYPSX20
Defective ic101In play mode turntable operates normally, in stop mode (poweron) turntable rotates backwards. in stop mode, ic102-2 output goesnegative 2.1v and inverting input remains slightly positive (pin 6). theoutput of logic pin 6 of ic101 remains at +1 volt. g
SONYPSX7
Defective q203Automatic function engages when power is turned on or off, andspeed varies. this only occurs when unit is cold.
SONYPSX7
Replacement motor will not mountDuring troubleshooting, we found that replacement motor(a-460-801-9a) would not mount properly. dimensions of motor shaft andspindle were different.
SONYPSX6
Open cap c205After several minutes of operation platter slows down and getsprogressively slower.
SONYPST25
Spacers to removePlatter scrapes on side opposite tonearm.
SONYPS212
Leaky q3Turntable speed is too fast.
SONYPS20F
Replacing stylusThe stylus of the moving coil cartridge for the ps-20f isreplaceable. the part number is nd206.
SONYMDR3L2
Wires breakThe distributor (norcal) has reported to me several brokenwires on these units. the wires break at the plug end.
SONYM200
Spring out of locationSwitch sw3 did not move to off position when stop buttonengaged. problem was spring (3-561-626-00) was off at stud end, not slideend.