Repair Guide: Common Issues and Fixes

Brand Model Fault Detailed Problem Solution By
SONYTAN77ES
No powerUnit has no power.
SONYCDXR88
Will not accept specific discThe eric clapton cd with the number 126074-2 re1 srct03will not play in cdx-r88. it will not load down. it gets stuck insidebecause the coating on the outside of the disc is not wide enough. itlets the led's light pass through so it does not think it
SONYKV27TS20
Shutdown, replace yoke and r-578Set in shutdown. r-578 dissipated, reading zero on the 27,12, and 9.3 volt lines.
SONYKV2680R
Shutdown, c-540 openSet would shutdown intermittently due to high b+ (145-150vdc).replaced str3035 in regulator circuitry to no avail. r-608 (20 watt220Ω) was cool. set also showed no ripple at normal line voltage.
SONYCPD1302
ShutdownSet would shutdown immediately at turn on. pin 6 of ic-301measures approximately 12 volts.
SONYSTRAV910
Microprocessor resetRefer to fpr number l0613. -hq comments: system malfunctions caused by the microprocessor lockingup can usually be traced to either a supply voltage problem, or aninterface problem. resetting, and in extreme cases, replacing the microis the only way to
SONYXM3060
Part number for rv-601 - rv-603The part numbers listed in the service manual for rv-601, 602and 603 are incorrect. the part number listed (1-238-826-11) is for aright angle mount pot, but the part needed is a vertical mount type.
SONYXM5520
Part number for rv-601Part number listed in the service manual for rv-601 is notcorrect. the part listed 1-238-826-11 is for a right angle mount pot, notthe vertical mount type needed.
SONYCDPS107
Intermittent skipping during playThe unit will intermittently skip while playing back a disc.the symptoms suggest a problem with the tracking/focus servo or with thepll block. adjustments will only slightly improve the situation, but willnot eliminate the skipping. new optics did not c
SONYKV27SXR10
No on screen display, replace ic-107Unit had no on screen display. all other functions normal.ic-107 (5 volt regulator) output was 7 volts.
SONYSTRAV910
Output transistors defectiveSeveral units to date with two output transistors defectiveand f-801/802 open. checked driver and other transistors - all ok.
SONYPVM2530
Interface cableCustomer wants to know what cable is required to interface apvm-2530 to a cga graphics card.
SONYKV2783R
Hue change above channel 35, adj aft coil slightlyColor and hue are fine from channel 2-35. when a channelabove channel 35 is selected, the hue will change flesh tones to green.tried service bulletin no. 273 but it did not help.
SONYSTRGX10ES
Front panel sub-chassis availabilityUnit was dropped. sub-chassis is bent. is it available? -hq comments: i checked with kansas city parts. the sub-chassis is notavailable as a separate part.
SONYTCFX160
No playback of prerecorded tapesIn playback mode, the line input signal is present at theline out jacks: unit is stuck in the record mode. ic-311/pin 42 is alwaysless than 1 volt. ic-381/pin 11 toggles correctly.
SONYWMAF604
Board does not match pcb layout in s/mServicer had two units of same model one unit matches thepcb layout in the s/m but the second unit does not. servicer states thatcorrect board is 1-629-871-11-i the unit that does not match the layoutis p/n 1-629-871-11-ii.
SONYSPP320
Handset changes channels on its ownAfter hand unit and base establish contact, the hand unitcycles to the next higher channel about every 12 seconds (just as itwould if the channel button were pushed). troubleshooting hint: removepower from base unit. hand unit cycling stops.
SONYMDP510
Green vertical bar in digital effectsUnit was normal in analog modes of operation. any operationusing digital picture processing displayed a predominately green verticalbar approximately two inches wide in picture.
SONYKV25DXR
Video has noise on highlightsUnit displayed noise on high frequency portions of video.noise was mostly red in color. video input to this ic looked clean -rgb outputs displayed noise in waveform.
SONYCDP608ESD
Garbled audio in both channelsUnit had distorted audio in both channels. found approx-imately 800-900hz mechanical resonance - similar to problem encounteredin cdp-c10.