Grundig Repair Tips




Search: Grundig
Results 554
MakeModel Ch.SymptomProblem SolutionSolutionBy:
GrundigCUC7301
St/by onlyC667 100µ 35v
GrundigCUC7301
Sound only - burst of line at sw on onlyLine osc at base of Line dr tr - nothing at collector. CT169 line osc buffer BC858B sm faulty. Note - HT is 105v when set working but rises to 129v in st/by or when non operational - normal?
GrundigCUC7301
Reduced width and line tearing when TV gets hot.Replace surface mount transistor CT169 BC858B
GrundigCUC7301
PSU rebuildCheck mains smoother C626 47µ 385v or PSU may need rebuilding again
GrundigCUC7301
Poor regulation of psusm diodes cd 654 and cd656 leaky. They are type LS4148 but standard 1N4148 ,s work ok.
GrundigCUC7301
Pic pulled across to rightCT169 BC858B sm leaky
GrundigCUC7301
Pic goes bright & may tripCT181 BC858B & CT186 BC848B sm on main pcb
GrundigCUC7301
off with a bangC669 1000pf had dry joints causing burn up of pcb. Following parts replaced :- 2.5A fuse, IC638 uC3842AN, T665 chopper tr MJF18004C, D662 BA157 s/c, D663 ZPD3.6 3.6v zener s/c, R663 18R, R661 220R hi res, R669 5w
GrundigCUC7301
off chopper tr s/c c-bT665 MJE18004C, D664, 666 1N4003, CD654,CD656 LS4148, IC630 UC3842A, D663 6.3v zener, R661 220R replaced & dry joint C669
GrundigCUC7301
low sound -stuck in hotel modehold 'i' button whilst switching tv on. Use rc arrows to select hotel mode then off
GrundigCUC7301
Low sound & no set up menuIn hotel mode - to exit - hold down "i" button at sw on
GrundigCUC7301
Field lin poor, width reduced & HT only 100vR666 & 667 in psu 0R82 had risen to 1R5 (values depend on crt size)
GrundigCUC7301
Dead - R542 10k or 13k o/cWhen replaced overheated again - crack in print by lopt
GrundigCUC7301
Dead - lop tr s/c & replacement ran hotCT169 BC858B buffer sm leaky
GrundigCUC7301
Dead - Chopper T665 blown plus -IC630, D633 3v6 zener, D662 BA157, bridge rects D621-4 1N4007, R661 220R, R663 18R, 3 x sm diodes under psu sect, dry joints C669
GrundigCUC7301
DeadC669 1000pf dry joints & burnt; MJF18004 T665 s/c; ZD663 had 25R reverse resistance, D624/621 1N4007 mains rects s/c & UC3842AN faulty
GrundigCUC7301
DeadDry joint C669 blows T665 & IC630
GrundigCUC7301
Blown psu caused by R661 220R going hi resalso replaced IC630 UC3842, T665 MJFS8004, D663 3v6 Zener
GrundigCUC73
WON'T START UPD663 SC
GrundigCUC720
Won't start, PS squeals, relay remains open.Change C655 100uF/25V cap.