mitsubishi Repair Tips




Search: mitsubishi
Results 620
MakeModel Ch.SymptomProblem SolutionSolutionBy:
MitsubishiEuro 10
Int dead esp from coldC905 220µ, C906 47µ C912 4µ7 in psu
MitsubishiEuro 10
int dead (could be ok for days)Same on dummy load proving psu fault. Opto coupler driver tr Q953 was to blame. BC547 suitable replacement
MitsubishiEuro 10
HT lowQ953 JC501Q error amp
MitsubishiEuro 10
Field lin faulty when coldGlue around pins of IC501
MitsubishiEuro 10
Field jitter - intDry joint R461
MitsubishiEuro 10
dead psu runsseveral electrolytics in psu leak electrolyte onto plug PB causing o/cs
MitsubishiEuro 10
Dead - Q901 chopper tr blows at sw onD909 3v zener s/c was the cause; also replaced R901 4R7 5w, IC901 TEA2164
MitsubishiEuro 10
DeadC905 470µ 25v
MitsubishiEuro 10
Black lines , poor sync, no txt (until warm)C959, 962 100µ
MitsubishiEuro 1
Diagonal pattern of dots across screenR914 100R in psu snubber cct o/c
MitsubishiEE4 CT25M5BT
Dead - blows chopper tr s/cmod, i.e. change the 220R res on print side of CRT base to 1K2 1/2watt,this apparantly prevents a surge from blowing the chopper at switch off
MitsubishiEE4 CT25M5BT
Chopper Tr blows aft few daysReplace Q901 (chopper), R901 (4R7 10W), D909 (3V Zener) and change 220R resistor on the print side of the CRT PCB to 1K2 1/2 watt.
MitsubishiEE4 CT21M5BT
Reverts to st/by aft 15mins with a sqealHT was too high at 137V, due to R954 (120K in this set) going high
MitsubishiEE4 (M5 models)
To enter service modePress & release S701 next to aerial socket, then press "9" on hset within 5 secs. Buttons 2 & 8 select adj code, buttons 4 & 6 adj data value. Button 1 cancels written data, button 0 stores data into EEPROM see article TV Jan 99 for more details
MitsubishiEE4
Trips once at sw on - ok on dummy loadTEA5101B RGB o/p chip IC660 s/c
MitsubishiEE4
Service mode accessingpress the service switch (s701, next to the aerial socket) and then button 9 within 5 seconds Press the * button to toggle between the VCJ or OPTION adjustment display. Press buttons 2 or 8 to increase or decrease the adjustment code number. Press buttons 6 or 4 to increase or decrease data value. After the adjustments, press 0 to write the adjustment data to the EEPROM.To cancel a change, press button 1 and all data adjusted since the last EEPROM write will be reset.TUN 0 Option settings for CT25AV1BS = SAT 1, AUD 10, ATS 1, STD 1, SYS 1, AV1 2, EEX -, SPK 1, EEP -, ABG 02, A1 02, AL 00, ADK 15, MNP 70, TXT -, FFT 1, VOL 74, HYP 1, SCP 20, FMP 23
MitsubishiEE4
Dead or int dead - brief flash of green led at sw onDry joints opto isol PC951
MitsubishiEE3W
Service mode accessPress MENU, 2, 3, 5, 7 to access service mode, then press * (star key). Use 2 & 8 to navigate up and down the options, 4 & 6 to alter values. Press 0 (zero) to memorise new value & the info turns red to denote "saved". Finally go to standby to exit menu.
MitsubishiEE3 CT25AV1BDS
Herringbone pattern, flashing lines etc with no pic for 5 minutes. Picture then slowly appearsC956 470uF 6.3V
MitsubishiEE3
Low contrast, smeary, f back linesR686 on crt base (1k8)