Sanyo | CBP2576A | Field top foldover & excess height | C703 100µ 50v | ||
Sanyo | CBP2576 ED0 | No sound | Carry out "start NVM" proc as described in manual | ||
Sanyo | CBP2576 ED0 | No E-W correction | ICP R756 (N20) o/c | ||
Sanyo | CBP2576 ED0 | Dead - whistle only - LOPTr 2SD1556 leaky | ,Overheats when replaced with int narrow pic, replaced C750 47µ 50v & C705 2µ2 50v for hi esr & check for dry joints in LOP section | ||
Sanyo | CBP2576 ED0 | Burning smell then dead | Burn up on pcb at line scan connector K-FF | ||
SANYO | CBP2576 | VERY BRIGHT RASTER SOUND OK | CHECK R534 22K OHM | ||
Sanyo | CBP2576 | Pin cush dist | Replace C750 2.2mfd | ||
Sanyo | CBP2576 | NO SOUND | REPLACE ICP853 AND IC1680 | ||
Sanyo | CBP2576 | JUST SNOW IN TUNING MODE | CHECK FOR CORRECT CONFIGERATION NUMBER 02014 TO ENTER SERVICE MODE PRESS MEMORY ON CT AND WITHIN 5 SECS PRESS MENU BUTTON ON REMOTE THEN ENTER THE ABOVE NUMBER | ||
Sanyo | CBP2576 | Excess width & pin cush dist | L750 & C653 | ||
Sanyo | CBP2572 ED1 | WHITE DOT PATTERN | DTI2223-06 , ON DIGITAL PCB | ||
Sanyo | CBP2572 ED1 | To reprog NVM memory chips | Press service button (thro' hole in set front) & VOL+ together - be careful - all previous data will be lost! | ||
Sanyo | CBP2572 ED1 | STRANGE E/W FAULT | CHECK DPU2553/75 ON DIGI BOARD | ||
Sanyo | CBP2572 ED1 | Q903 s/c R301 ( 3R9 ) o/c | Check R3165 D/J and TEA2260 | ||
Sanyo | CBP2572 ED1 | Int loss off air signals | Q173 D/J | ||
Sanyo | CBP2572 ED1 | EW faulty | DPU2553/75 deflection proc chip | ||
Sanyo | CBP2572 ED1 | Dead | R301 3R9 15w surge res o/c, Q303 2SC4429 chopper tr s/c, R315 dry joints caused it-also IC301 TEA2260 faulty | ||
Sanyo | CBP2572 ED1 | Dark & lacking contrast | Unable to get "OK" indication when adj A1 volts in service mode. IC501 VCU2136 on digital pcb faulty - pt no 409 212 0608 | ||
Sanyo | CBP2572 ED1 | Blank raster, no sound or OSD | 2 x NVM chips on sigs panel sus; can be replaced or reprog | ||
Sanyo | CBP2572 ED1 | BLANK RASTER NO SOUND NO ON SCREEN DISPLAYS . MEMO | REPLACE OR TRY RE-PROGGRAMMING BY PRESSING THE SERVICE SWITCH AND VOLUME PLUS BUTTON TOGETHER . SERVICE SWITCH BEHIND SMALL H |