GRUNDIG 2401 Repair Tips




Search: 2401 GRUNDIG
Results 31
MakeModel Ch.SymptomProblem SolutionSolutionBy:
GrundigCUC2401
Trips at sw onL519 shorted turns
GrundigCUC2401
Tripping - at switch on.R637 1k control.
GrundigCUC2401
Tripping - at switch on - may come on.C661 ( 7u f , 25v )
GrundigCUC2401
Switching to standby - my take days.Tripler.
GrundigCUC2401
Startup - failure to start intermittent.Set HT R637 ( 1k ) may ch Ok , LOPTX if going off af few mins
GrundigCUC2401
Standby - intermittent shut down.Set HT control R637 ( 1k ) may check Ok.
GrundigCUC2401
Sound - mutes on video rec playback.Mod ABL module.
GrundigCUC2401
SET GOES TO STBY VERY INTTRIPLER US
GrundigCUC2401
No sound or - Picture - intermittent.Suspect the set-EHT control ( especially if made by Preh.
GrundigCUC2401
No soundCould be TDA2595, TDA130 or SDA2011-A003 micro
GrundigCUC2401
No soundTBA130 chip not working due to C2276 470µ s/c
GrundigCUC2401
No soundC2276 ( 470uf ) s/c.
GrundigCUC2401
No raster - line collapseLOPTx o/c
GrundigCUC2401
No pic - sound okNo vid o/p pin 8 TDA3566 - Tr2523 BC548C s/c
GrundigCUC2401
No pic - blanked outField only half normal height due to supply only 10v to field chip - R525 0R33 hi res
GrundigCUC2401
Low controllable soundTuner
GrundigCUC2401
Int switches to st/byTripler
GrundigCUC2401
Int start upTDA4600 chopper chip
GrundigCUC2401
Int loss of pic caused by field collapse26v supply pin 8 TDA2655B was only 4v - D2758 BY298 & C2758 1000µ replaced
GrundigCUC2401
INT FIELD COLLAPSED2758 INT OC