GRUNDIG CUC7350 Repair Tips




Search: CUC7350 GRUNDIG
Results 15
MakeModel Ch.SymptomProblem SolutionSolutionBy:
Grundig CUC7350
Dead - mains fuse shatteredD60013/4 mains rects s/c, chopper FET T60020 IRFBC40 s/c used BUZ90 UC3843 replaced as prec,caused by dry joints chopper tfmr
Grundig CUC7350
Dead - +8v supply absentR61021 15R safety res in 8v reg o/c
GrundigCUC7350
Width varies with pic content - HT varies between 119-129vR60027 0R56 in curr sensing network - also check R60028 in parallel - values vary with screen size
GrundigCUC7350
Unstable HTR60028 0R68 o/c - check it out of cct!
GrundigCUC7350
TrippingR60027/28 0R46 gone hi res
GrundigCUC7350
St/by onlyLM317T reg s/c by its heatsink clip
GrundigCUC7350
No soundcheck sm trs to left of audio IC - mute sound in st/by & when told by micro - BC848C faulty in this case
GrundigCUC7350
No HT controlHT pot R60027 increased in value from 0R68 to 1R5
GrundigCUC7350
mains fuse o/c, BUZ chopper tr s/cdry joint C60029 470pf 1.6Kv also check D60011-14 & D60023/4 rects
GrundigCUC7350
Int start upC60031 100ยต 35v in psu
GrundigCUC7350
Dead IRFBC40 chopper MOSFET failureDry joints C60029 470pf. Check R60027/28 0R46, R60022 10R, D6011-14 D60023-24 1N4007
GrundigCUC7350
Dead - Chopper FET & 2 rect diodes s/cdry joint on C600 - blew again later due to arcing between FET & heatsink
GrundigCUC7350
Dead - 2.5A fuse blackenedT60020 IRFBC40 chopper tr s/c; D60013 1N4007 mains rect s/c; C60029 dry joints; R60023 1N4003 s/c; R60027 0R56 o/c
GrundigCUC7350
DeadChopper FET & control IC partial cure but all volts low until R60027/8 0R56 1w reistors replaced
GrundigCUC7350
"E" instead of "OK" shows when storingSw on with "Prog -" button depressed to clear "fault"