Search: PH200N
Results: 6

PH200N Repair Guide: Common Issues and Fixes

Brand Model Fault Detailed Problem Solution By
PHILCOPH200N
League display offZd5 and zd4. Q17 shortedDinetronic This email address is being protected from spambots. You need JavaScript enabled to view it.
PHILCOPH200N
It doesn't turn on, just the blue light stays on.Corrupted u3Replace u3 or re-recordVander CDs de Quixadá CE
PHILCOPH200N
Clean and resolder.U9 with bad contact.Clean and resolder.eletronica bianca ipira-ba
PHILCOPH200N
Turns on the blue volume LED lights up, but the display does not turn offOn the front panel board the c11-104 =100k 50v ceramic short I replaced, which caused the short comes to the main board, very close to the photocoupler the 2 resistor changed and opened r152-330r smd and r153-2k2 smd, already on pin d14 - fr107, tsound is an open resistor r137 - 2r2 smd and q17 - mpsa92 in short, near this transistor r139 - 100r with smd leak, I replaced these components and the display started working againDefect resolvedEletronica Hally
PHILCOPH200N
Does not turn on - does not turn on standbyDiode d14 fr107Medium diode good but when it warmed up it started working againAdriano de Souza
PHILCOPH200N
XX
The red LED doesn't even light upSaleSubstitute o ic tda 7265toninho da eletronica