W322NS Repair Tips
Search: W322NS
Results 4
Results 4
Make | Model Ch. | Symptom | Problem Solution | Solution | By: |
---|---|---|---|---|---|
Goodmans | W322NS | Procedure to enter sevice mode | Switch off tv, hold in VOL+ button on tv and STANDBY button on remote, switch back on at mains switch then release buttons, set will then come on in service mode.Adjust with PROG. + - and VOL + - store with yellow button | ||
Goodmans | W322Ns F19 | Dead with regular ticking from psu | Dry joints C68, 69 & 70, D24 BY288 s/c, C69 22nF low cap & BU508D faulty tho' checked ok | ||
Goodmans | W322Ns F19 | Dead apart from tripping PSU | LOPTr s/c which blew when replaced - 15nF 2kv flyback tuning cap never been soldered in properly | ||
Goodmans | W322NS | Tripping - LOPTr s/c | Caused by 15nF 2kv flyback cap never being soldered |