Grundig Repair Tips




Search: Grundig
Results 554
MakeModel Ch.SymptomProblem SolutionSolutionBy:
GrundigSuper Color 8615/8415/8215/8115
Won't start, no EHT present.Di518 Sced. It's located behind the large 15uF nonpolar cap.(C532)
GrundigSuper color 8472/8672/8272/8872/9272
Won't search.Pin 5 of syntheseizer module, should have 3,5 volts. If not, change R4111 (1,8 volts).
GrundigSuper color 8472/8672/8272/8872/9272
R621(6,2ohms) smokes immediately after switch-on.Replace thyristor Ty503 type17127
GrundigSuper color 8472/8672/8272/8872/9272
R621(6,2ohms) smokes immediately after switch-on.Replace thyristor Ty503 type17127
GrundigSTR20A
Blank raster sound ok.Check for blob of solder across pins on video/RGB connec
GrundigST95-775
Poor FocusFocus cap 68pF 12,500v
GrundigST70-775DPL
No pic via tuner or scart - unable to access menusRe - format eeprom ; On this set you do this by holding down P- as you switch on. This loads the emergency data set. If as on mine this appears to have no effect the set is probably also locked in hotel mode. To rectify this hold the i button on the remote whilst switching on. This will allow access to a limited service menu. Use the arrow keys to scroll down to Hotel Mode and switch it off, then scroll to the bottom of the menu and select end with mem and push ok. Switch off the set and power back up whilst holding the P- key and the eeprom will reformat. Switch off then back on again and select the menu system by pushing i then ok. Scroll down to service menu and push ok, on the next menu scroll down to service code and enter 8500. This brings up the full service menu and all adjustments can be made from there. Note the hardest thing to set is the afc which you select on the menu but adjust with coil 3025 inside the set. Basically if there is a directional arrow on the service menu under the afc setting you have to rotate the coil in that direction until the arrow disappears. In practice you have to go through this procedure but remembering to memorise all the settings (by selecting end with mem) about 4 times, switching off the set each time.
GrundigST70755/9DPL
No sound & o/p IC getting hotCaused by momentary contacts on mains sw perm making
GrundigST70-400
Int start up & no R/C - no st/by lightR617 10k7 & R616 6k8 both 7w dry joints
GrundigST63560
Line shake (double image)IC526 CPC Pt no GR8305338140
GrundigST63560
E/W corrR503 2R2 & IC430 TDA8350Q
GrundigST63560
Blows LOP Tr 2SD1432Dry joints scan coils
GrundigST63460
Thin white line in the center of upper half of screen.Change D2334 and D2344 with 1N4148. Caution! They seem to be O.K with a VOM.
GrundigST63460
DIM BLANK RASTER AND REDUCED HEIGHTD2334 LEAKY IN FIELD CCT
GrundigST63460
Dim blank raster - no picture.D2334 ( TD190 ) leaky.
GrundigST1772/9TOP
Field foldoverTDA8350Q chip
GrundigSE7086TOP etc
int no sound - when increased gives popping noiseMains sw st/by contacts int
GrundigP45-440/1GB
No pic - sound ok - faint arcing noisedry joints ww res R516 in line stage
GrundigP37-440
Tuning - random channel change.IR IC TFMS3300 or 4300 with metal screen over it.
GrundigP37-440
Sound - random volume up & down.IR IC TFMS3300 or 4300 with metal screen over it.