itt Repair Tips




Search: itt
Results 510
MakeModel Ch.SymptomProblem SolutionSolutionBy:
ITTTrimline
Standby - stuck in standby.TR1401 o/c , on CMC301.
ITTTrimline
Dead - relay clicks on - mains on board.Black fat MR856 ( or BYT13/600 ) diode by LOPTX.
ITTTrimline
Blank raster.T400 ( BC237 ) or ( BC171 ) part of beam limiter cct.
ITTTrimline
Bars across screen about 1" wide.C1425 ( 2.2uf ) o/c.
ITTTrimline
122v rail going low after 1/2 hour.Change T617 ( BC238 ) .
ITTST38767
No pic - sound okTPU2732 Txt proc chip
ITTST38767
Field bounceDry joints regs
ITTST38767
DeadTDA2170 field o/p chip s/c
ITTST35767
DeadField o/p chip had blown
ITTST3487
No picture.IC401 ( TDA2170 )
ITTST28TXD2 S4SQ
Dead - chopper tr BU908 s/cChange elects & TEA2165 in psu
ITTST28TX
No sound/blank raster - no R/C & corrupt displayreset line to micro IC701 stuck at 4v. CCU SEL06 & MDA2061 leaky from reset pins to chassis. No sound caused by D701 1N4148 in mute line leaky. All caused by dry joints on reg chassis connection
ITTSP71D1
line driver tr VK22 blows few mins aft sw onCK22 2µ2 100v
ITTSP71D1
Dead with S2000AF lop tr s/cfailed aft replacement - CK51 8n7 1.6kv faulty
ITTPico S3
Dead apart from brief led flicker at sw onLOPTx
ITTPico S3
Dead - life restored if scan coils dis'dWidth control coil on scan coils has shorted turns
ITTPico S2
Dead - no relay click or displayMains st/by tfmr o/c pri
ITTPico S2
Dead - no relay click at switch on.Standby mains transformer primary winding o/c.
ITTPico S
St/by onlyrelay clicks at sw on but no HT to LOP Tr; C701 10µ 350v faulty
ITTPico S
Pulling/bouncing/int loss of soundC212 10µ 50v in CMR800 (top of can)