jvc Repair Tips




Search: jvc
Results 369
MakeModel Ch.SymptomProblem SolutionSolutionBy:
JVCC140EKY
Dead - st/by onlyHT at D921 but does not get past Q923 (HT reg) No power control from micro, Dry joints on Xtal X001 on micro sub panel
JVCC140EKY
Dead - st/by onlyDry joints emitter of Q924 in psu
JVCC140EK
No chan store - No clock pulses pin 10 IC001Come from pin 31 IC002 but lost along way - fitted wire link
JVCC140EK
Int startup.R905 180k gone high.
JVCC140
SET SWITCHES OFF , CHANGES CHANNEL , ADJUSTS volume.CRYSTAL ON SUB PANEL DRY
JVCBYX chassis
No memorise chans or settingsIC001 MN1226S, C106, C107 on station select module
JVCBYX chassis
Loss of some chansIF module SBY-F004A proved to be heat sensitive - retune T102 V C Osc coil
JVCBYX
Int tuner drift & patterningDry joints IF module
JVCBX11
tuning drift from cold4 sm electrolytics on sub panel C015 22µ 6v, C016 0µ47 50v & C014 3µ3 50v
JVCBX11
Tuner driftReplace sm caps C014, C017 3µ3 50v; C015 22µ 6.3v & C016 0µ47 50v in station selector module
JVCBX11
No chan store (search tune ok)Check print, thro conns etc in Stn Sel Module - replacement expensive
JVCAVS25SD4EK
Comes on briefly to show good pic in EXT3 then reverts to st/byPossible EEPROM corruption - press "I" and "Audio Mute" simultaneously on handset. This will put it into test mode. Another quirk of some EEPROM problems is that the set will often switch to standby when going into or out of Service Mode or when pressing "VSM Reset".
JVCAVK21T
Dead aft lightening strikeChange STRS-F6653 / opto couple / Q941 / Q942 / D945 6v2 /IC901S1854 error amp
JVCAVA14M2
Int cuts outCheck for cracked print around LOPTx
JVCAV32WFP1EK
St/by onlyC966 0.01µ s/c
JVCAV32R25EK(S)
Sound very dist on NICAM - ok on monoR chan o/p from MSP chip (Nicam processor) IC631(pin 31) 6v p-p & badly clipped - L chan ok - chip faulty
JVCAV29TS2EK
Powers up with EHT then shuts down with brief small raster visibleC521 fb tuning cap o/c
JVCAV29TS2EK
Int sw offD405 on LH side of FOP chip o/c (in X ray prot) - can remove Q573 X ray Tr to prevent sw off whilst check for cause of fault
JVCAV29TS2EK
Field - jumping like dry joint22k resistor on print side under glue had dry joint
JVCAV29SX4
Small pic at sw on then reverts to st/byC521 line tuning cap changed value 4n 1.5kv