sanyo CE28WN4 Repair Tips




Search: CE28WN4 sanyo
Results 8
MakeModel Ch.SymptomProblem SolutionSolutionBy:
Sanyo CE28WN4B
Procedure to disable protection mode for fault findingThe protection mode can temporarily be disabled to prevent the set going into standby during fault finding by disconnecting R648 note: safety procedures must be followed !!
SanyoEB6-A28 CE28WN4-B-01
Service mode accessPush green fastext key while pushing prog down key on front of set. To adjust geometry make sure pic size is set to "Full" before starting, select "Wide" under options & select parameter using prog + & - adj with vol + & - and switch off to store. Mod kit available from SEME for this fault
SanyoCE28WN4B
St/by only with LED flashingR620 120k hi res
SanyoCE28WN4B
Int Cuts out with LED flashing (prot mode)To disable prot mode dis R648 - after a while crt heaters went out due to dry joint
SanyoCE28WN4B
Excess height & E-W faultyFit mod kit B10H04N1C or B10H04D0L if Dolby Pro Logic set
SanyoCE28WN4 EB6A
Excess width & no E/W after LOPTx replacementD469, C463 (10nF 50V) and Q462 (used a 2SD1207),C465 (33nF 50V) and D463 both s/c
SanyoCE28WN4
St/by only shortly after fitting B10H04NIC mod kitIC802 the PROM which is part of the kit was faulty
SanyoCE28WN4
EEPROM ProblemsThere is a mod for this set, part No B10H04NIC the micro doesn't get enough info on shutdown and reverts to default values, hence very big pic! Service mode is accessed by pressing the green button on the remote followed by prog down on the set.