Grundig CUC5360 Repair Tips
Search: CUC5360 Grundig
Results 6
Results 6
Make | Model Ch. | Symptom | Problem Solution | Solution | By: |
---|---|---|---|---|---|
Grundig | CUC5360 | Store ,tuning , analogue controls inoperative | Check memory Ics IC847/8 also bad earths which could be cause of Ics going faulty | ||
Grundig | CUC5360 | No vid via scart skt | Sw carried out in tuner/IF chip. Check CT2512/3/4/7 sm types BC848/858 | ||
Grundig | CUC5360 | int tuner | check for dry joints on xtal | ||
Grundig | CUC5360 | Col int | Replace 4.43Mhz red trimmer | ||
Grundig | CUC5360 | No NICAM sound - whistle on mono sound | MSP2400 chip in IF module | ||
Grundig | CUC5350 CUC5360 | "P1" DISPLAYED AFTER PROCESSOR CHANGED | R836 FROM 10K TO 22K ( OLD SDA 20562 A 006 NEW SDA 20562 A 506 Grundig 8305-157-580 ) |