sharp D3000 Repair Tips
Search: D3000 sharp
Results 12
Results 12
Make | Model Ch. | Symptom | Problem Solution | Solution | By: |
---|---|---|---|---|---|
Sharp | DV5903H D3000 | Soot & whitewash effect & no sync/txt | IC1404 VCU2136A vid I/p ok at pin 39 but dig o/p pins 5, 6, 7, 8 & 9 not all active - chip faulty | ||
Sharp | DV5903H D3000 | Blank white raster | IC1404 VCU2136A AD/DA converter - chip suspect | ||
Sharp | DV51083H D3000 | Faint raster which can't be turned off by R/C or hor bars | C1485 47µ 50v, C1442 10µ 16v on dig vid panel. Also change C732 & C710 in 5v supply & C719 1000µ 6.3v in 5VM supply | ||
Sharp | DV51083H D3000 | Dead. When the collector of the 2SD1546 line outpu | The line output transformer was faulty. Fit a replacement and power the set up slowly via a variac. If at about 100V input th | ||
Sharp | DV51083H D3000 | Dead - HT present | C715 1000mfd 16v in 5VM supply | ||
Sharp | DV51083 D3000 | Trips after LOPTx replacement | FOP chip TDA8175 s/c & supply res 1R o/c | ||
Sharp | DV51083 D3000 | Tripping continously - int originally | C715 2200 16v LT res cap low cap | ||
Sharp | DV51083 D3000 | Dead - HT ok when LOP dis'd | LOPTx faulty | ||
Sharp | DV5103H/DV5903 D3000 | Chrom info out of register with lum | Small plug in non volatile memory chip IC1411 on digital PCB | ||
Sharp | D3000 DV6603H | clicking noise from speaker, gets worse when warm | replace IC0302 RHIX1433BMZZ | ||
Sharp | D3000 | Shuts down int | R628 1k & R746 22k hi res | ||
Sharp | D3000 | Faint pic after loptx replacement | C606 0µ22 between pins 6 & 7 of loptx leaky |