sharp DV3751 Repair Tips




Search: DV3751 sharp
Results 7
MakeModel Ch.SymptomProblem SolutionSolutionBy:
SharpDV3751H
TEXT FAULTY , CHANNEL 4 , SOME TRANSMITTERS ONLY4 ) REPLACE R825 2.2k WITH 1.8k ( Sharp VRS TV1JD182J ) 5 ) ADD 100pF ON PRINT SIDE , ACROSS R871 6 ) FIT 100pF CAP IN POSITION C2
SharpDV3751H
int start up, dead,widthR601 5R6 5w varied in value & int o/c
SharpDV3751H
BLANK VIDEO FIELD LINES ACROSSREPLACE MICRO AND MEMORY Sharp CHIX1463CJ7 Sharp RHIX1492BMN2
SharpDV3751 DV5131H
CHANGING MICROWHEN CHANGING MICRO REPLACE NVM ALSO IC1001 SDA20561- ( A535 ) RH-IX1492BMN2 IC1002 NVM Sharp CH-IX1463CJH7
SharpDV3751
NO TEXT - AND NO CLOCK FUNCTIONCHECK LOCATION 21 IN NVM ( LINK PINS 2-6 EDGE CONNECTOR PRESS MODE , REMOVE LINK. )
SharpDV3751
No AFC - poor tuningR214 sometimes gets damaged if set dropped or if rear cover not put on correctly
SharpDV3751
No AFCCheck R214 for damage - by tuner