sharp DV3760 Repair Tips




Search: DV3760 sharp
Results 12
MakeModel Ch.SymptomProblem SolutionSolutionBy:
Sharp DV3760H
Dead, led flashing red/green at first, then going to red standbyReplace C604 1000uF, 16v elec. cap. It is in the decoupling circuit for the 5 volt supply
Sharp DV3760H
Will not work, standby red LED flashingC604 in the 12V line is bad
SharpDV3760H 4BSA
No start upC604 1000mfd 16v o/c
SharpDV3760H 4BSA
Dead but all psu secs ok apart from 13vD602 faulty tho' measured ok
SharpDV3760H
VERTICAL STRIPES ON LEFT SIDE ESP DARK SCENESFIT 1K8 IN PLACE OF JUMPER WIRE R895 Sharp VRD-RA2HD182J
SHARPDV3760H
DEAD WITH S/C ACROSS LINE O/P TRANSISTORCHECK D601 1N4937
SharpDV3760H
Dead - no o/p from psuD601 1N4997 HT rect leaky
SharpDV3760H
DeadS/C across LOP stage; D601 1N4937 600v 1A s/c
SharpDV3760 4BSA
Shuts down straight away at sw onReplace LOPTx (HR 7559) plus R649 27R 1/2W, R637 27R 1/2W, R640 56R 1/2 W + 2 elect caps between base/emitter Q1010
SharpDV3760
Tripping PSU & LED red/green flashingC604 1000ยต 16v in sec of psu
SharpDV3760
Pic displaced 3" to rightR604 seems to be the cause (wrong value?) removing it centralised pic
SharpDV3760
Deads/c on ht line traced to LOPTx