sanyo EB1 Repair Tips
Search: EB1 sanyo
Results 8
Results 8
Make | Model Ch. | Symptom | Problem Solution | Solution | By: |
---|---|---|---|---|---|
Sanyo | ED0 / EB1 | To enter service mode | Press & release diamond memory key on front ("Factory" shows on screen), press Index/Menu on hset within 5 secs; 1st tab on serv menu highlighted to allow entry of config code (02014) from handset. Pressing the R/C menu key again changes OSD to next setting, then alter with "Vol+" & "Vol-". To alter next parameter press sound button (under Vol+ button) to highlight next tab. Recommended values:- HO=02140; SO=01012; S1=00081; AO=00186; YO=00050; PO=15861; ZO=01369; P1=01665; Z1=00087; SP=00009 | ||
Sanyo | EB1 | st/by only after brief EHT crackle | 5 & 12v regs being turned off by pin 7 of µ. When lifted line stage works with field coll. No frame pulses from DPU2553 µprocessor - chip u/s | ||
Sanyo | EB1 | St/by only aft brief EHT rustle | No 5 or 12v supplies due to st/by command pin 7 µ; when dis'd pic came up with field coll. Replacing fop chip no diff - DPU2553 chip u/s | ||
Sanyo | CBP2580 EB125 | This set would shut down interrnittently: the peri | The set could be made to run indefinitely by entering the service mode ( menu on the set's control panel , followed by menu on | ||
Sanyo | CBP2580 EB1 | To enter service mode | Menu on set's control panel, followed by menu on R/C handset | ||
Sanyo | CBP2580 EB1 | Shuts down int - runs ok in service mode if IM bus run is stopped | Fault somewhere on the IM bus - NVM3060 EEPROM on digiboard cured fault | ||
Sanyo | CBP2580 EB1 | Colour lost & pic shifted to right when heated | Xtal X403 pt no 610 217 1037 | ||
Sanyo | CBP2580 EB1 | AFTER 2-3 Hrs COLOUR GOES AND PICTURE SHIFTS TO R | XTAL X403 DRIFTING Pt No 610 217 1037 |