Grundig | GSC100 | R607 - repeated resoldering of R607. | Di2502 ( 4.7v ) zener. | ||
Grundig | GSC100 | No frame. | Di447 ( 1N4007 ) and/or TDA1170. | ||
Grundig | GSC100 | Line break up. | C2502 ( 100uf , 16v ) on EHT control regel baust PCB. | ||
Grundig | GSC100 | IF EHT IS VERY HIGH | CHECK DI508 IS OPEN | ||
Grundig | GSC100 | Frame - bottom foldover - cramping at top. | R2522 ( 2.2k ) goes high. | ||
Grundig | GSC100 | Dead. | Di511 or C2502 ( 100u f , 16v ) on EHT control regel baust PCB. | ||
Grundig | GSC100 | Dead. | R607 o/c , faulty thyristors , insulation in line o/p stage. | ||
Grundig | GSC100 | Dead - blowing 3.15amp fuse. | EHT cap jumping across to degaussing coil. | ||
Grundig | GSC100 | Dead - blowing 3.15 fuse - intermittently. | EHT cap arcing. |