RM95 Repair Tips

Model:Make: Symptom:

Sponsored Links

Search: RM95
Results 3
MakeModelCh:SymptomProblem SolutionSolutionBy:
SonyRM95CONVERTING NEW RM95 TO OLD TYPE To convert the new (adjustment) RM-95 to the old type for useas a straight wired remote control, remove the solder bridge on the holdswitch and remove labels on front and back.
SonyRM95MANUAL FOCUS WITH RM-95 How do you manually focus with the RM-95? -HQ COMMENTS: This works on units with TTL autofocus. You must firstpress the focus button, then operate the focus motor manually by using thebuttons located diagonally down and to the right of the focus button
SonyRM95MODIFICATION FOR TEST ADJUSTMENT MODE If you modify the unit as per bulletin No. CSV-3, 91, youcannot get into test adjustment mode.