GRUNDIG Repair Guide: Common Issues and Fixes

Brand Model Fault Detailed Problem Solution By
GRUNDIGCUC5360
Store ,tuning , analogue controls inoperativeCheck memory ics ic847/8 also bad earths which could be cause of ics going faulty
GRUNDIGCUC5360
No vid via scart sktSw carried out in tuner/if chip. check ct2512/3/4/7 sm types bc848/858
GRUNDIGCUC5360
Int tunerCheck for dry joints on xtal
GRUNDIGCUC5360
Col intReplace 4.43mhz red trimmer
GRUNDIGCUC5360
No nicam sound - whistle on mono soundMsp2400 chip in if module
GRUNDIGCUC5350 CUC5360
"p1" displayed after processor changedR836 from 10k to 22k ( old sda 20562 a 006 new sda 20562 a 506 grundig 8305-157-580 )
GRUNDIGCUC5350
White lines & 2 of each r-g-b- lines on top 3 ins of screenCheck ht & replace c538 47u 35v
GRUNDIGCUC5350
No sound at sw on; if vol + on r/c operated sound returns for duration of button pressAerial socket loose was reputed to be the cause !!! (socket came adrift)
GRUNDIGCUC5310
Int pic10v ripple on 200v ht line due to c681 4µ7 350v o/c
GRUNDIGCUC5310
Dead chopper sc when replaced blows againD681 sc
GRUNDIGCUC5310
Dead - t644 chopper tr s/cS1624 wickman fuse in 300v supply o/c, d681byv38 200v rect on sec psu s/c
GRUNDIGCUC5310
Dead - fuse si624 1.25at o/cT644 buz90 chopper tr s/c
GRUNDIGCUC5305
No i/p via scartIc2350 tda5931-5 on if pcb
GRUNDIGCUC5303
Ps. transistor blown. changed chopper tr, and tda4605, but they were blown again. occasionally the set before blowing the smps may run for a while.Check/replace r632 270k resistor.
GRUNDIGCUC5303
No front or r/c controls aft couple of hoursIr rx
GRUNDIGCUC5301
R/c inop - no response from ir rxReplace ir unit tfms4300 4 leg type, with tfms5360 3 leg type not all 3 leg type will do
GRUNDIGCUC5301
Osd dim & outline only - ok when no sigs presentIc2541 tda3566 col dec chip u/s
GRUNDIGCUC5301
No r/c4 pin rec u/s - replace with 3 pin version
GRUNDIGCUC5301
Int pic - sound okDry joints t568 tr heatsink - mech stressed
GRUNDIGCUC5301
Field collapseD401 12v zener s/c and hi ht due to 2 x 47µ caps