Sony Repair Guide: Common Issues and Fixes

Brand Model Fault Detailed Problem Solution By
SONYKV2691R
Muted picture and no vip operation and no remote, d-062The picture was muted and sometimes after warm up pix wouldcome on. ic052 pin 2 was high. found d062 installed backwards atfactory. d062 was installed cathode to b+. the board and the boardlayout show the diode anode to b+. the schematic shows catho
SONYSL10
Solenoid plungerThe original part # 1-454-349-41 was subbed to 1-454-365-51.the new solenoid fit the unit, but the collar on the plunger would notclear the mounting pieces on the unit. the original plunger had nocollar. we need to have the plunger changed on this sub.
SONYWMF15
Damage caused by batteryNegative end of battery heated up and pushed cabinet out. -hq comments: new batteries from eveready and duracell may have shortedinside the unit. they have a plastic skin instead of old metal. underthe skin is the positive cylinder, and negative termi
SONYKV2691R
Dark band across crt, replace q-204The unit had a dark band across the crt about 2/3 up from the bottom. the colors were also weak and somewhat out of phase.
SONYSLHF600
Distortion on beta hifiProblems with beta hifi playback and record. customer livesless than 1/2 mile away from a broadcast station transmitting on 1350kc.traced problem to the cable tv line that was hooked up to the fm input ontheir denon dra-400 receiver. the denon had a 75
SONYKV1972R
No manual control, replace ic105All front panel controls on the unit became inoperative (snd,pix, chan, pwr), however, the remote worked on all functions.
SONYKV2680R
No vip, replace ic-105No vip operation. all other functions worked correctly.
SONYKV1390R
Shutdown, replaced r559The unit would go into immediate shutdown. we shorted c535 todefeat the shutdown circuit and then ran the unit up on the variac. allother circuits were functioning properly.
SONYKV1993R
Locked in one mode/no channel change, replace v out ic501The pll controller/ic103 was locked up. the channels wouldnot change and audio/pix outputs were at minimum. we found the verticalpulse to be missing at the controller/ic103. this was caused by adefective vertical output/ic501.
SONYXR75
No fmThis unit had no fm, all other functions worked fine. foundthat there was no output from the prescaler to the pll.
SONYBMC110
Slow startup of audio erase functionAt the beginning of a recording, old audio would not beerased for approx. 14 seconds. after this time, normal erasure ensued.
SONYSL2305
Intermittent tape jam in eject modeAt times, when ejecting cassette, the tape would not be takenup completely and would get stuck in the deck area. viewing the ejectoperation, i noticed that the tape was always lagging behind the threadingring, sometimes more than others. this caused th
SONYKV25XBR
Intermittent distorted display on screen at randomAfter set got warm, on occasion the channel numbers mightflash on and off on the screen. also, weird words appeared on the screenwhere you normally would view the time and date. there was no set patternof words nor did they spell out anything, just a j
SONYCCDM8
Capstan motor failureCapstan free running, no control. c fg (+) missing, connectedto pin 19 of su-16 board.
SONYKV25XBR
Dead unitUnit came in dead. found rectifier shorted, d655 on gb bd.still did not have 140vdc. convertor output okay, problem has to be t652or t653 on gb bd. i could see connector output up to c655 on ga bd(both sides) but not on t653 or t652. not sure which o
SONYKV1992R
No memory, replaced r609No last channel memory. no channel add-erase. set wouldcome on with various volume levels.
SONYKV2675R
No power on with remote, ic-050 on "t" boardUnit would not turn on with rm-718 remote. all other func-tions ok. unit would turn on at front panel, and after set was turnedon, all functions on remote and front panel operated properly. unitwould not respond to this one function only.
SONYKV2601
Sub partKansas city is supplying a 2sc3559 (p/n 8-729-204-94) perthe latest microfische. the new part is a t047 case style instead of thet060 original. installation of the new part requires use of spaghettiinsulation on the leads, and looks terrible. -hq comm
SONYSLHFR30
Green color during pause and betascanColor shifts to green during pause and betascan (ff and rew).pin 9/ic4 on yc-30 board chroma ok during pause and betascan but outputpin 11/ic4 chroma is bad during pause and betascan.
SONYSL30
Betamax antenna switch failureAntenna continues to feed thru to vhf out connector while unitis in playback mode. this problem is showing up on several models usingthe same switch. the customer is often on cable. some units that havefailed have less noticeable leakage thru the swit