Brand | Model | Fault | Detailed Problem | Solution | By |
---|---|---|---|---|---|
DAEWOO | GB14F8T1 | No vol adj - osg stuck ½ way | Ic1703 24c08p eeprom - pre-prog by daewoo from seme @ £18 | ||
DAEWOO | GB14F7T1 CP420 | St/by only | R804 47k start up res | ||
DAEWOO | GB14F7T1 | Won't switch on with tape stuck - at/by only | No volts at 6v reg ic1806 - p803 plug/skt has 8v in but no 8v o/p due to dry joint on/off sw | ||
DAEWOO | GB14F7T1 | Sound disappears int | (ic) i501 a tda8374a mounted on the vcr pcb. | ||
DAEWOO | GB14F7T1 | Dead - psu ok but no lop | Hairline crack by loptr coll tp loptx | ||
DAEWOO | DWX28W5GB | Impurity | Check degaus coil not trapped by set back causing them to go o/c | ||
DAEWOO | DVT2082P | Red missing | Q552 2sa1266 on crt base | ||
DAEWOO | DVT2082P | Int dead | Dry joint c817 100µ - remove plastic strut to see | ||
DAEWOO | DVT1482P CP310 | Sound absent in tv mode - ok in pback | Check rhs edge connector for dry joints/damaged print on video unit | ||
DAEWOO | DVT1482P | Dead with burning smell | Loptx | ||
DAEWOO | DVT1482P | Dead - mains fuse blackened & chopper tr s/c | Tda4601 control chip & c811 100µ 35v | ||
DAEWOO | DVT1482P | Dead | F4ah fuse o/c, chopper tr 2sd2499 s/c - used 2sd1555 in lieu, c811 100µ 16v hi esr, 220µ 25v hi esr | ||
DAEWOO | DVF522P | Dead | Check/replace c53 1µ 100v, d63 rd16f or ma7160 16v zener, c64 680µ 16v, | ||
DAEWOO | DTE28G7GB CP785 | No sound/pic - psu & line drive ok | Tda8385j fop chip faulty | ||
DAEWOO | DMQ2159 CP315 | Excess brill with fb lines at sw on - ok when heated | C426 3µ3 250v in 190v supply | ||
DAEWOO | DMQ2072 | No signals & no osd | R256 18r o/c in st/by reg cct | ||
DAEWOO | DMQ2059 | Int trip | On/off sw momentary contacts perm connected | ||
DAEWOO | DMQ2057 | Bright smeary pic | 190v to rgb low - c426 3µ3 250v | ||
DAEWOO | DMQ1454P | Storing of tuning or analogue levels inop | D912, d903 leaky & check tactile switches for leakage | ||
DAEWOO | CP775 | Various faults on chan change; eg e-w, blank raster, snow or st/by | Data line down to 4v (must be 5v) - d708 5.6v zener is leaky also replace d709 5.6v zener to be on the safe side. |