Brand Model Fault Detailed Problem Solution By
GRUNDIGCUC3300 CUC3400
Poor focusUsually the focus pot on tripler faulty but check c433 1000µ for s/c, if its 16v working - fit 25vw (can cause scan coils to overheat)
GRUNDIGCUC3300
Poor purity & focus.C433 ( 1 , 000uf , 25v )
GRUNDIGCUC3300
Poor focus or picture so dim it can hardly be seenC433 1000uf 25v ( not 16v as originally fitted ) do not run set in this condition as the scan coils may overheat and crack cr
GRUNDIGCUC2800
The tripler had failed. after replacing it the setMicrocontroller chip type sda2011 -aoo5 . make sure that you get the right one for the set.
GRUNDIGCUC2800
Sound low & distU2829b ic sound chip
GRUNDIGCUC2800
Sound from one chan only & no brill adjMicro sda2011-a005 faulty
GRUNDIGCUC2800
No soundCheck tda6200 sound proc & u2829b sound dem chip
GRUNDIGCUC2800
Dead - psu working okRelay contacts
GRUNDIGCUC2800
Arcing from loptx former to adjacent componentsTripler faulty
GRUNDIGCUC2600
Tuner - snow or blank raster from cold.Sprinkle in tuner.
GRUNDIGCUC2600
Int blank raster or snowy picTuner
GRUNDIGCUC2600
Dead - no o/p from psuC631 100µ in psu
GRUNDIGCUC2500
Sometimes switches to st-by. eventually does not startup at all.Replace tda3640 chip
GRUNDIGCUC2490
No sound.Short pins 1,3 of tda6200 with 13,15 repectively.if sound comes on, replace tda6200.
GRUNDIGCUC2490
Comes on with the volume at max. no adjustment of volume is possible.Push "n" in the keyboard, set the balance in the middle and adjust volume to the desired level. it should work o.k after this.
GRUNDIGCUC2410
No startup - may try at first.C633 ( 100u f , 25v ) o/c.
GRUNDIGCUC2410
No sound - may have had a flash over.Ic tda2595
GRUNDIGCUC2410
No soundTda2595 muting set
GRUNDIGCUC2410
No pic, sound & txt ok blank rasterNo vid i/p at pin 8 tda3566 - bc 548c tr2523 s/c c-e
GRUNDIGCUC2410
Dead - spillageReplace 1.25 & 2.5a fuses, chopper tr bu508a. now works but r616 2k7 start up res overheats - r617 thermistor u/s. code 07902 - wve