Search: GRUNDIG
Results: 948

GRUNDIG Repair Guide: Common Issues and Fixes

Brand Model Fault Detailed Problem Solution By
GRUNDIGCUC2401
Int field collapseD2758 int oc
GRUNDIGCUC2401
Int deadHt pot r367 1k
GRUNDIGCUC2401
Goin into standby after few mins.Loptx ( if comes on agn from cold ) freezer dont work!
GRUNDIGCUC2401
Dead.D666 s/c.
GRUNDIGCUC2401
Dead with silent trippingD666 in snubber network s/c
GRUNDIGCUC2401
Dead psu tries but fails to startC633 100ยต 25v o/c
GRUNDIGCUC2401
Dead ht ok at psu o/pNo ht at loptx - pri winding o/c
GRUNDIGCUC2401
Dead - faint tripping heardDry joints loptx
GRUNDIGCUC2401
DeadR637 1k ht preset hi res
GRUNDIGCUC2401
Bu508 getting too hot.Change tda8140.
GRUNDIGCUC2400
Tuning - will not tune in.5v rail down to 4v , ic676 ( mc78mq5ct )
GRUNDIGCUC2400
Sync - intermittent frame sync or bounce.Mod available.
GRUNDIGCUC2400
St/by only4m7 resistor in psu connecting the 2 earth rails o/c
GRUNDIGCUC2400
No blueR760 15k on crt base o/c
GRUNDIGCUC2400
No blueR769 on tube base oc
GRUNDIGCUC2400
Low soundTuner faulty
GRUNDIGCUC2400
Flashing & intermittent picture.Poor contact on crt base board , & cap shorting.
GRUNDIGCUC2400
Dead.Bu508d.
GRUNDIGCUC2201
Tripping, thumping noise & no displayCombi tfmr o/c sec windings n & l
GRUNDIGCUC2201
Tripping - then comes on.Set ht control r637 ( 1k )