Search: MITSUBISHI
Results: 1346

MITSUBISHI Repair Guide: Common Issues and Fixes

Brand Model Fault Detailed Problem Solution By
MITSUBISHIEE4 CT21M5BT
Reverts to st/by aft 15mins with a sqealHt was too high at 137v, due to r954 (120k in this set) going high
MITSUBISHIEE4 -M5 MODELS
To enter service modePress & release s701 next to aerial socket, then press "9" on hset within 5 secs. buttons 2 & 8 select adj code, buttons 4 & 6 adj data value. button 1 cancels written data, button 0 stores data into eeprom see article tv jan 99 for more details
MITSUBISHIEE4
Trips once at sw on - ok on dummy loadTea5101b rgb o/p chip ic660 s/c
MITSUBISHIEE4
Service mode accessingPress the service switch (s701, next to the aerial socket) and then button 9 within 5 seconds press the * button to toggle between the vcj or option adjustment display. press buttons 2 or 8 to increase or decrease the adjustment code number. press buttons 6 or 4 to increase or decrease data value. after the adjustments, press 0 to write the adjustment data to the eeprom.to cancel a change, press button 1 and all data adjusted since the last eeprom write will be reset.tun 0 option settings for ct25av1bs = sat 1, aud 10, ats 1, std 1, sys 1, av1 2, eex -, spk 1, eep -, abg 02, a1 02, al 00, adk 15, mnp 70, txt -, fft 1, vol 74, hyp 1, scp 20, fmp 23
MITSUBISHIEE4
Dead or int dead - brief flash of green led at sw onDry joints opto isol pc951
MITSUBISHIEE3W
Service mode accessPress menu, 2, 3, 5, 7 to access service mode, then press * (star key). use 2 & 8 to navigate up and down the options, 4 & 6 to alter values. press 0 (zero) to memorise new value & the info turns red to denote "saved". finally go to standby to exit menu.
MITSUBISHIEE3 CT25AV1BDS
Herringbone pattern, flashing lines etc with no pic for 5 minutes. picture then slowly appearsC956 470uf 6.3v
MITSUBISHIEE3
Low contrast, smeary, f back linesR686 on crt base (1k8)
MITSUBISHIEE3
Long time to come onC955 2200µ for 11.5v supply
MITSUBISHIEE3
Lock up & memory problemsReplace c955, c702 & r3d68 also change value of r702, r213 & r214 to 1k ¼w
MITSUBISHIEE3
Grey scale variesCrt bias request bit could not be set to 00 with g2 control - not ic201 dec/tbase gen chip.cured by replacing tea5101 rgb o/p chip & diodes d655/6/7 1n4148 on crt base
MITSUBISHIEE3
Green led lit - no other activityHt secondary supplies ok- no line drive. ic702 eeprom may need reprog
MITSUBISHIEE3
Dead; 2a fuse blown violently & chopper q901 s/cReplace q901 s2000n, ic901 tea2261, opto coupler pc951 tcdt1124g. check d909 zener rd3.0fb2 & r908 0r33 2w & r909 0r22 2w
MITSUBISHIEE3
Dead- initially long time to come onC914 47µ 35v, c955 1000µ 16v
MITSUBISHIEE3
Dead apart from flashing red/green ledsC955 1000µ 16v
MITSUBISHIEE3
Dead - q552 s/c due to high htC914 47µ 35v o/c
MITSUBISHIEE3
Dead - lop tr s2055n leaky then no line drQ551 fully conducting, q501 jc501-r u/s
MITSUBISHIEE3
DeadCct prot o/c - uprated to 3.15a from 2a also could be start up res r915 15r 2w, r922, r921 & r902 22k 2w
MITSUBISHIEE3
DeadAvn5-kit is available when q552 has gone s/c - includes r713 1k, r726 5k6, q552 2sd1556, q901 s2000n, r508 3k9 5w, r991 4r7 10w, d909 rd3.0fb2 zener, an additional cap c720 22pf
MITSUBISHIEE3
Crushed whitesQ952 8v reg dry joints