Brand Model Fault Detailed Problem Solution By
PHILIPS2A
Frame collapse - blows chip after few days.Change ic , c2571 ( 100uf ) , d6646 ( byd33g ) , c2646 ( 1 , 000uf )
PHILIPS2A
Frame bounce when coldThis was cured by replacing c2550 1 uf (4822 124 40242).
PHILIPS2A
Fine grill effect over pic - can be intIc holders on txt panel int - remove chips & solder in directly
PHILIPS2A
Field poor linearityC2575 4u7 63v
PHILIPS2A
Field collapseTda3654q f o/p chip & c3571 100µ 25v hi esr
PHILIPS2A
Field chip fails regularlyC2571 , c2565 , d 6570
PHILIPS2A
Faint pattern of vertical lines.With text fall out. solder text ics direct to panel.
PHILIPS2A
Excessive width - preset ( r3595 ) has no effect.R3602 ( 15Ω ) fusible o/c ( no 23v rail ) , drys on t5611.
PHILIPS2A
Excessive widthCheck r3602 15Ω ( safety )
PHILIPS2A
Does not tune. right channel number in display.In search tuning mode the tuning voltage of channel selector remains 33v. r3740 (5r6; 4822 050 25608) broken in citac module.
PHILIPS2A
Does not start.Check c2670 (68nf polyester flat foil 63v). check c2681 6,8 uf
PHILIPS2A
Destroys line trRemove line drive tx clean pins and refit
PHILIPS2A
Dead.Standby thyristor 6727 ( bt151 ) s/c.
PHILIPS2A
Dead with whiningR3602 1r safety res o/c; c2602 10µ 63v s/c; r3601 5r6 safety res o/c
PHILIPS2A
Dead with whiningLoptr leaky - used bu508v; dry joints line dr tfmr
PHILIPS2A
Dead with 300v collector but11afD6663 1n5062 leaky
PHILIPS2A
Dead with 2a fuse o/c, 2 mains rects s/cReplace cnx62 optocoupler & tr7686 bc369
PHILIPS2A
Dead set , overvolts thyristor firingC2698 ( 4.7mfd ) o.c.
PHILIPS2A
Dead or int deadOk on dummy load - c206 u/s and bulging slightly
PHILIPS2A
Dead - trippingOk on dummy load - loptx faulty tho checked ok on tester