Brand Model Fault Detailed Problem Solution By
PHILIPS20DV1
Poor response to infra red handset operationIt is possible that vcrs of the above types and having a week code of 9042 or 9043 may not always respond to signals from the remote control handset. cause:a small number of capacitors fitted in position numbers 2021 and 2022 on the operating panel (jdc)
PHILIPS20CT4626/05T
Cracking & banging.Drys on loptx.
PHILIPS17PT165B AA5AB
Dead after lightning strikeReplace 1571 (630ma wickman) and retune stations (tuning memory had been wiped out).
PHILIPS17PT161A
To adj tuningDedicated r/c reqd pt no 4822 218 21249 & must press both diamond keys together to enter tuning mode
PHILIPS17HT5403
To adj sound level of this "hotel" tvPress set up then "m" then scroll down options to vol - adj vol then press "m"
PHILIPS17CE1358/05B
Not cabbageTda2541 faulty - (pin 26 tda3561a = 2.2v not 10v as marked on cct)
PHILIPS14VP274/05
Sound ok no pictureIf no heaters replace r3532/3537 at rear of tv pcb both 4r7 fusible
PHILIPS14VP184
Dead, blowing fuseReplace posistor
PHILIPS14VP163
White raster with flyback lines then standbyReplace r3592
PHILIPS14TX3504 TX3
Frame collapse.R423 ( 33k ) o/c.
PHILIPS14TVCR240/05
Tripping due to high htD6335 s/c ug06b (in4148 does) & r3343 5r6 o/c in feedback reg cct
PHILIPS14TVCR240
Tripping - ht rises to 170v (should be 110v)R3343 5r6 safety res o/c pt no 4822 052 10568, d6335 s/c pt no 4822 130 8330
PHILIPS14TVCR240
Start up problems after replacing ts7352When ts7352 is replaced, it can happen that the set doesn't start up properly. there are 2 possible solutions for this problem: - use sgs type mtp3055e (4822 130 63726). - in case of a motorola type mtp3055v (4822 130 60838), add a 22 uh coil soldered i
PHILIPS14TVCR240
Start up problemsWhen the set is switched on by the mains-switch while a cassette is in the set, the front led starts blinking, but the set doesn't start. solution: check the primary voltage (ubat) and adjust this for 14" sets to exactly 101.5 volt. (see chapter 3.1.1 of
PHILIPS14TVCR240
Spare part informationA repair kit , containing pulley shaft + worm shaft (pos. 47+48) is delivered with codenumber 4822 310 10657. this kit can be used for all turbo- and eco mechanisms !
PHILIPS14TVCR240
Spare part informationConcerns sets produced from week 9608 until 9647. motor holder with reverse prism included: in sets produced before week 9647 the reverse prism is a fixed part of the chassis and not available as a spare part. from week 9647 onwards a motor holder (pos.
PHILIPS14TVCR240
Spare part infoAs a service spare part, the picture tube will be changed back to a philips model. its code is: 4822 131 20623. if your set was previously equiped with an orion picture-tube, please make additionally the following modifications when mounting this philips
PHILIPS14TVCR240
Set produces audible noise in stand-byAdd a small lebl (leading edge blanking) pcb, to avoid auto oscillation of transformer 5330 (or 5331). a modification letter is included with the lable pcb. this pcb is available with service nr. 4822 214 12173. since production week 9723 this circuit is
PHILIPS14TVCR240
Set produces audible noise in stand-byAdd a small lebl (leading edge blanking) pcb, to avoid auto oscillation of transformer 5330 (or 5331). a modification letter is included with the lebl pcb. this pcb is available with service nr. 4822 214 12173.
PHILIPS14TVCR240
Service manual informationDeviations between 14tvcr240/01 and 14tvcr240/01n: for 14tvcr240/01n, use the service manual of 14pv162/01. additional codenumbers: position description codenumber 1 frame assy 4822 464 51055 1/5 lift