PHILIPS | L01.1L AC 29PT4631-25PT5531-29PT4640 | Intermittently loses tune or (loop). - | R3958 amended. | ||
PHILIPS | L01.1L AC 29PT4631-25PT5531-29PT4640 | It loses time when it goes to stand by. - | Check capacitor 2351 (low capacity). | ||
PHILIPS | L01.1L AC 29PT4631-25PT5531-29PT4640 | Has no colors - | Check crystal: pal m crystal abc f226 3, 57611 18sp; NTSC Crystal ABC C 3, 579545 18SP, used with "TDA8360 N5". | ||
PHILIPS | L01.1L AC 29PT4631-25PT5531-29PT4640 | It has no date, clock, | Check capacitor 2111. | ||
PHILIPS | L01.1L AC 29PT4631-25PT5531-29PT4640 | Does not work (it remains switched off). - | Measure voltage on the collector of the transistor 7502, if it is high, it is possible that the integrated 7200 is defective. | ||
PHILIPS | L01.1L AC 29PT4631-25PT5531-29PT4640 | Does not open vertically - | Check leak capacitor 2407. | ||
PHILIPS | L01.1L AC 29PT4631-25PT5531-29PT4640 | It works intermittently (see slide2). - | C111 flashing. | ||
PHILIPS | L01.1L AC 29PT4631-25PT5531-29PT4640 | With dark band in the center (i). | R3229 (1m) pin 42 of the bimos causes stains in the drizzle and intermittent vertical closure. | ||
PHILIPS | L01.1L AC 29PT4631-25PT5531-29PT4640 | With dark band in the center (i). | R3501 (power driver horiz.) causes beam or bending of the beam in the middle of the screen. | ||
PHILIPS | L01.1L AC 29PT4631-25PT5531-29PT4640 | With vertical bar(s) or stripes - | C2233 (r-y signal) causes red bars or spots on the side of the screen after heating. | ||
PHILIPS | L01.1L AC 29PT4631-25PT5531-29PT4640 | Blurred or deformed characters. - | Check capacitor 2938 (120pf), depending on the location it can be removed. | ||
PHILIPS | L01.1L AC 29PT4631-25PT5531-29PT4640 | Device does not come out of self-demonstration. | Press menu on the remote control, select special functions, select demonstration and press osd on the remote control. | ||
PHILIPS | L01.1L AC 29PT4631-25PT5531-29PT4640 | Voltages below the specified (vo, +b,..) - vo 140 (with 130v) | Check, replace zener diode 6541. | ||
PHILIPS | L01.1L AC 29PT4631-25PT5531-29PT4640 | Does not change screen formats. | Some printed circuits had a "print" error in the initial production period in position 6464, when replacing this item, check the positioning according to the electrical diagram. | ||
PHILIPS | L01.1L AC 29PT4631-25PT5531-29PT4640 | Jagged image (see train1). | Check resistor 3241, possibility of it being open or altered. | ||
PHILIPS | L01.1L AC 29PT4631-25PT5531-29PT4640 | Flash on the sides with white screen. - | Check capacitor 2209, replace with 10µf elco capacitor (4822 124 40248). | ||
PHILIPS | L01.1L AC 29PT4631-25PT5531-29PT4640 | Turn off inter. or protect (rew 3 for vcr). | Check possible changes in capacitor 2455 (47µf). | ||
PHILIPS | 29GX1898/78R | Dark screen - no image or active progressive | Displayed, volume does not vary. disconnect plug a13 (on the in panel), if the image appears, check the ghost cancellation rca socket must be open between pins 3 and 4. | ||
PHILIPS | 29GX1898/78R | Dark screen - no image or active progressive | R 3652 opened or amended. | ||
PHILIPS | 29GX1898/78R | Dark screen - no image or active progressive | 3456 resistor open. |