Search: Philco
Results: 4758

Philco Repair Guide: Common Issues and Fixes

Brand Model Fault Detailed Problem Solution By
PHILCONI
CPH-05
Dead, burning q703Power supply transformer ferrite loose
PHILCONI
CPH-05
Intermittent on and offIc901
PHILCONI
CPH-05
Inoperative with open r923Zd904
PHILCONI
CPH-05
Inoperative with normal power supplyC914
PHILCONI
CPH-05
Image wavy or distortedC905
PHILCONI
CPH-05
Burning zd901Ic901
PHILCONI
CPH-05
Image with retrace and then turns offSah19
PHILCONI
CPH-05
No colorChange crystal
PHILCONI
CPH-05
Keeps disarmingI will go 13
PHILCONI
CPH-05
With mat, without videoIic701 e r719
PHILCONI
CPH-05
No color, low voltages in IC502 (1 and 9)C512, c515
PHILCONI
CPH-05
Inoperative with open r720Ic 601 short
PHILCONI
CPH-05
Inoperative with blinking LEDIc101, r917, r925, r907, r908, c706,ic401
PHILCONI
CPH-05
Inoperative or intermittentCold welding c911, replace c706 with polyester
PHILCONI
CPH-05
Entering intermittent st-byR713 open
PHILCONI
CPH-04
DullC304
PHILCONI
CPH-04
Retrace lines on topD304
PHILCONI
CPH-04
Turn on and offZd304
PHILCONI
CPH-04
Turns off intermittentlyPriapism
PHILCONI
CPH-03
Little shineFlyback