Brand | Model | Fault | Detailed Problem | Solution | By |
---|---|---|---|---|---|
SAMSUNG | CI5070AN US60A | Dark pic | D503 1n4003 diode hi res - check o/p from 12v reg ic802 - it may be low confirming faulty part | ||
SAMSUNG | CI5070AN | No line drive. ht 125v ok, but 15v supply to jungle ic low | C808 150uf 400v | ||
SAMSUNG | CI5070 | No sound or vision, coming out of stby | D801 (measures ok) | ||
SAMSUNG | CI5061AT | Field collapse - int | Dry joints fop chip | ||
SAMSUNG | CI5061A | Sound has buzz/motorboating | C612 o/c | ||
SAMSUNG | CI5061 P68SA | Brightness varies | Q905 2sa539-y on crt base | ||
SAMSUNG | CI5061 | Pic shifted to right | C404 2n7 & check r420 820k | ||
SAMSUNG | CI5052XT P68 | No s/v , with sby light flickering | Sdh209b ic801 | ||
SAMSUNG | CI5052XT | St/by only | C852 470µ, c418 1µ 250v hi esr, q402 2sd 1651 (loptr) s/c, r826 1r ½w o/c- replace loptr with correct type (i didn't & it went s/c again 3 days later!) | ||
SAMSUNG | CI5052XT | No sound/vis with st/by led flickering | 125v ht only 70v; ic801 sdh209b | ||
SAMSUNG | CI5052XT | Hum bar | C851 100µ 400v mains smoother o/c | ||
SAMSUNG | CI5052X | St/by only | 86v ht, r813 o/c | ||
SAMSUNG | CI5052X | Int low brightness | A1 pot on loptx & c907 10nf 2kv | ||
SAMSUNG | CI5052X | High ht should be 125v | C852 470µ 16v | ||
SAMSUNG | CI5052AT | Height reduces with bounce | Ic402 12v reg mc7812 | ||
SAMSUNG | CI5052AT | Frame collapse | Check d412 and r412 | ||
SAMSUNG | CI5052AT | Field lowers when warm then bounces | Ic402 mc7812 | ||
SAMSUNG | CI5052 P68 | "store" & "channel" in flash on screen | 1n4148 diodes in key strobe lines to micro ric01 leaky | ||
SAMSUNG | CI5052 | No sigs & partial field collapse | B+ (12v) to tuner low at 1.4v. r419 10r safety res o/c (not shown in manual) | ||
SAMSUNG | CI5038Z | Tripping with ht low at 102v instead of 125v | Smr earthing was suspect on heatsink (new type device recently fitted) i psu |