Sony Repair Guide: Common Issues and Fixes

Brand Model Fault Detailed Problem Solution By
SONYKPR4600B
No picture, replaced q-956Unit had no picture. sound would vary up and down. found lottransistor shorted.
SONYKP5040
Vertical noise bar, connection change on r3383 and r3384Unit had dark vertical line in the center of the screen, onlow channels. disconnected resistors r3383 and r3384 where they jointogether and connected them to pin 2 of ba-9 connector.
SONYKP4000
Poor on no soundThis unit powered up but there was poor or no sound/picture.we found r107 on the q board to be defective.
SONYFD30A
Poor focus, replaced crtThis unit had poor focus. the tube had internal shortputting 500 volts on the focus pin.
SONYKX1901
Intermittent shut downThis unit intermittently shut down. we found the lead fromthe flyback to the hvr control to have a poor connection where the wireconnects to the metal retaining cap. the resulting arcing caused theunit to shut down. it was not possible to properly rep
SONYKX1901
Weak sound on left channelLeft channel output is lower than right channel.
SONYKV4100
Mechanical damageFlywheel gear broken. at least 25 units are due intohollywood fsc with same complaint. no tape deck operation. so far 5units repaired. four out of five had defective gear. gear must bestrengthened.
SONYKV2670R
No raster, r-526 open, c-527 open and q-504 leakyThis unit had no 1000 volt g2 screen voltage. r526 was open.c527 was blown in half. d508 was changed for safety. q504 was leaky.
SONYKV2649RX
Poor focus on the screen, replace t861Set had poor focus on right side of screen (about 4 inches).by tapping t-861, the focus would get worse or better.
SONYKV2649RX
No function, replaced d021Set cannot be turned off, except by the master switch.channel up/down, volume up/down, picture, color etc. do not work. foundd021 leaky.
SONYKV2602
Vertical distortion, replace c516This unit would play for approx. 20 minutes with no problem.after the circuit had sufficiently heated up the vertical would start tocollapse until there was only about 1/2 inches of deflection. we foundc516 to be defective. monitoring the resistance ac
SONYKV1975R
No vip function, replace ic103The above 6 units came randomly in a period of 2 weeks from2 servicers (all in the city), for no vip function. two could be resetfor vip, the rest remain with no v/p function. acquired a few new chipsand installed with very good results (cx-520-111n).
SONYKV1913
No soundNo sound, but picture ok.
SONYKV1554RWP
Intermittent on/offWill come on intermittently.
SONYKV1354R
Dead, replaced ic-003This unit would not turn on and all other functions wereinoperative. we found ic-003/pll controller to be defective.
SONYKV1221
No tuner lock in, replaced n2503This unit worked fine except that intermittently the tunerwould not lock in on the c position. when the n position was selectedduring the failure mode then the c channel information would be present.we found the neon lamp n2503 to be the cause of the pr
SONYKPR4600B
No pictureSet would lose display and scan channels. no picture.traced problem to open t502.
SONYKP7220
Erratic tuning and distorted picture, replaced r547, r546Picture is dark and shrunken in on sides, will not staytuned on channel selected. tuning is erratic.
SONYKX2501A
No sync, remove copper insert from u1001There have been several units brought into the fsc for repairwith the symptom of no sync. the problem has been traced to theprotective insert installed on the u1001 input terminal. this plug shortstogether pins 1 and 18. this turns on q1329/sync switc
SONYKV2675R