Search:
Results: 87441

Repair Guide: Common Issues and Fixes

Brand Model Fault Detailed Problem Solution By
SONYKV2691R
Intermittent loss of y signal, poor solder on 9v reg q-204The unit would very intermittently loose the y signal. onlychroma would be present on the crt and the chroma level would be low. wefound the problem to be poor connections around the 9 volt regulator,q-204. when in the failure mode, the 9 volt line wo
SONYKPR41DS2
Dark picture - g2 low, replaced d-5052The crts were all low in brightness. all voltages to the crtschecked ok except the g2 was a little low (max. 230v). we found dioded-5052 on the e board to be leaky. replacement resolved the problem. -hq comments: when d-5052 becomes leaky, it can no
SONYCDXA10
Commander hook-upWhen using your bench test commander, replace the unit'sexisting cord (p/n x33295361), which is about 15 feet long, with the cordfrom an rmx2 (p/n 1-559-687-11), which is about 1 foot long. this makesworking on cdx-a10s easier. the cords are interchang
SONYSLV353UC
No power after ac re-connectionIf ac cord is disconnected, power will not come back on whencord is re-connected. all other operations are normal.
SONYD25
Unit will not power up - cold solder d-409 cathodeUnit has no power. this is the fourth unit with this problem.
SONYGV8
Will not ejectWhen the eject mechanism unloads halfway, unit stops.troubleshoot mechanism, no fault found. checked pulse for off sensor, nopulse. measured for 5v on pin 2 of cn-006 of sv-34 board, found 5vmissing. checked voltage around q-112, found emitter of q-11
SONYMVCC1
Disk pack will not eject, adjusted plate ass'yDisk pack will not eject.
SONYCCDV5000
In pcm mode no right channelNo right channel in pcm mode.
SONYKV32XBR65
Gains time, see s/b tvp-0087Installed capacitor modification as per service bulletin0087. it has resolved the problem. before addition of apacitor you couldunplug the set, plug it back in and it would work for 15 to 20 minutes andthen start gaining time. -hq comments: thaks for t
SONYKV20TS20
Severe pie crust effect, open c-501Unit exhibits severe pie crusting. scope pin 11 showingdistorted in horizontal drive output. indicating a bad ic-301. thenreplaced ic-301 problem still exists. did a component by component checkfor open capacitor in horizontal oscillator drive sectio
SONYMVCC1
Jamming of disk packs, replaced loading gearUnit would jam while ejecting.
SONYMVCC1
Eject motor runs for 1 second then stops, replace ic601When ejecting a disc pack, the eject motor would run for abouta second then all motion would cease.
SONYMVCC1
Spindle motor runs continuously, replaced stepping motorSpindle motor runs continuously.
SONYMVCC1
No power, replaced d301 - d308Have seen diodes d301-d308 fail several times, more commonlygoing short circuit. -hq comments: thank you for the information.
SONYD7
Unit powers up - spindle motor/no torque to spin diskUnit powers up, display comes on, fop tries to focus butspindle motor does not have enough torque to spin disk.
SONYMVCC1
Intermittent operation, replaced q329 on ma-1 boardIntermittent operation of unit.
SONYMVCC1
No power, replaced q310 on ma-1 boardNo power.
SONYKV27HSR10
Cold solder connections on t-501Unit dead, no horizontal drive pulse.
SONYCCDF35
Will not eject tapesWill not eject cassettes.
SONYITA750