Search:
Results: 87420

Repair Guide: Common Issues and Fixes

Brand Model Fault Detailed Problem Solution By
SONYVCL4058
Use of 4x teleconversion lens with 8mm camerasCan vcl-4058 be used with 8mm cameras? -hq comments: we have checked with tokyo and they have advised us asfollows: ccd-v8afu, v110 - compatible v8, v3 - not compatible
SONYCCDV8
No camera powerCamera dc-dc converter (dr902) goes dead when aw-1 board isconnected to it via cn702. -hq comments: lift each wire from cn702 (one at a time) until you canisolate which voltage is being pulled down. check for shorted 2v or 3vregulator circuit on aw-1 b
SONYBMC550
No capstan or drum rotationPressing record button, no capstan or drum rotation. allsignals from system control ok. found no output from pin 12 of ic201,cs-5 board. ic201 was defective.
SONYBMC660
Unit will not white balance under mercury vapor lightingCustomer taped outdoor football game under mercury vaporlights. unit would not auto-white balance and would not produce any redcolor during playback. -hq comments: i contacted tiffen mfg. and they suggested a combinationof #50 red, #20 yellow, and a #2
SONYSTS555ES
Output was being muted intermittentlyUnit would intermittently activate mute relay. also, stereolight would flicker. checked discriminator and mpx vco. both were withinspecs. control signal causing mute circuit to activate came from micro-processor. further tracing found mute output fr
SONYKV1981R
Cannot turn off set, replace ic103After set on for a couple of hours press power button pixgoes black then comes back. picture setting is at minimum when pixreturns.
SONYKV2657R
Incorrect part number, cover neckIncorrect part # 9-910-999-51 correct part # 4-334-942-00 -hq comments: we will publish service bulletin on this.
SONYSTRVX5
Wrong part number in manualsIncorrect p/n 1-121-361-00 correct p/n 1-123-361-00 -hq comments: we will issue a service bulletin.
SONYKV2084R
Remote control button failureExcessive and repeated remote control failures due to remotecontrol sheet rubbers are open. the following buttons are usually open:picture/volume/channel.
SONYTCFX510R
Unit comes on in rec modeWhen the unit is turned on it appears as if the record buttonhas been pushed and is waiting for the play button to be selected. also,the tape counter does not work nor will the rec/play timer function.
SONYTAAX360
Incorrect part number for ic-101Both ic
SONYCCDV8AFU
Four vert. lines in picture during e-e or camera recordingFour evenly spaced vertical lines appeared in pix during e-eor camera recording. also appears during self recorded playback.
SONYKV2644R
Retrace lines, replaced r749Retrace lines in pix.
SONYKV2645RS
Audio pop on channel change, adj t207Loud audio pop on channel change, power on, or power off.changed t207 on a board, this reduced pop somewhat, but did not eliminateit. adjusted t207 while changing channels to eliminate popping.
SONYRME100V
Picture dropouts on tape recorded on evs-700u from ccd-v8afuDropouts occur in lp recording mode.
SONYSLHF400
Snowy picture in betascan when warm (approx. 1 hr of use)After running the unit for approx. 1 hr, when cue or reviewis used picture is extremely snowy. unit was very temperature sensitive.
SONYXR77
No loadingCass will not load. this happens on models xr-50, xr-70.and xr-77. 385 deforms with use (years) to the point where loading isincomplete. 387 joint lever assy can latch 386 threading arm assy. removecass holder, then carefully bend upwards to restore 9
SONYESR10
Wrong part numberReference numbers 229 and 230 are crossed. in orderingreverse pinch roller (item 230 on page 26 of service manual), i receivedforward pinch roller (item 229). -hq comments: we will issue a s/b.
SONYKPR4110
Cp6001 open, replaced cp6001This unit is used with a panasonic vcr pv-1770 and when thevcr comes out of the scan mode (review) the unit will go into hv shutdownand sometimes open cp-6001. this is caused by a problem with the vcrchanging the horizontal freq. this unit opened cp-60
SONYSL5200