Repair Guide: Common Issues and Fixes

Brand Model Fault Detailed Problem Solution By
SONYKV2647R
Intermittent no channel reception, replace r-025This unit would not tune stations intermittently. found r025/22kΩ resistor increased in value to 35kΩ on mf board.
SONYKV2647R
No channel 11 reception, replace ic002This unit would not tune channel 11 in all the way. thescreen displayed a herring bone pattern. at first it appeared to be anaft problem. however further investigation revealed ic002 memory to bedefective.
SONYKV2645R
Popping sound on channel change, replaced t207Servicer had replaced t207, hoping to cure a highly inter-mittent sound loss problem. set was returned to shop and i noticed apopping sound on channel change.
SONYKV2601
Intermittent all channel displayIntermittently unit would go to all channel display lightslit. could not tune in any station when all lights locked in. foundnegative line off flyback ok but after going through coil l511 found thatthe negative voltage sometimes missing. also serial n
SONYKV2602
Intermittent shut down, replaced ic501, d501, q501, t502Intermittently goes into hv shut down. changed ic501, d501,q501, t502. also reduced the value of r572 to satisfy the adj. procedure. -hq comments: probably this type of shut down is caused by defective hvrblock. the 15.2 +/- 0.1v specified in adjustm
SONYKV1946R
Picture distortion (v), replace ic502Would not scan top 2 inches of picture v-size and lin. hadno effect, remove blanking and fills up picture.
SONYKV1923
Picture distortion (v)Unit came in with 2 of vertical. we found c520 shorted andthis restored height but the linearity was poor. found c529 to havechanged in value - evidently damaged. c520 must have tantalum replacementfor best results.
SONYKV1922
Picture distortion (pin)Severe pincushioning and poor width. q513 pin amp shorted andc810, ic546 to be dried up. after replacing these parts the pin and sizewere substantially improved. however during the first 5 minutes of opera-tion the left and right sides were pulled in
SONYKV1910D
Picture distortion (h)Unit had severe horiz. foldover and would short the sg613 atfull voltage. the problem is very elusive to find. have seen severallately.
SONYKV1723D
DeadServicer had replaced horiz. output sg613 and regulator2sc867a. replaced again, also r556 in start ckt. monitored voltage dropacross r807 - too much. replaced c813 and c809. set came on, however,now no g-y from chroma demodulator. checked waveforms
SONYKV1722
Picture blankingThis unit was in full blanking. the b+ regulator was workingfine. we found the 11v zener off the base of q606 (evp-1) to bedefective. the zener threshold was approx. 5v.
SONYKV1515
Static related damageThis unit has now been repaired 3 times with static relateddamage to the tuner as the problem. a visit to the customer's homerevealed nothing out of the ordinary. we then carefully gift wrappedthe tuner cluster with 3m electric tape #1245 and grounded
SONYKV1515
Defective vc driveWe have found many units with defective vc drive transistors.the transistor generally fails within the first 30 days of operation.this is not a 2sc9450r 2sc1364 transistor. in fact i have not seen thisvariety in a sony product.
SONYKV1510
Picture distortionThis unit had bright bars at the left and right hand side -about 1 wide. the balance of the picture was close to normal althoughlacking detail. we found c532 to have opened up. this filters the b+ tothe video outputs.
SONYKP5040
Mechanical mis-operation, lubricated piston armsMirror would jam in either the inward or outward movement of the mirror. there was a hue shift in the center of the screen.
SONYKP5040
Channel drift off station, replaced leaky c209After about 10 minutes, channel would drift off station.found c209 had resistance.
SONYKX2501
Blanking display, replaced r472, sm error r472 labeled r453Unit displayed blanking problem. 2 wide bar on the left sideof the crt. i could find no problem except base of q401 was -1v (printcalls +0.3). i found r472 missing.
SONYKX2501
No picture control, replaced ic13021) rgb lines in the picture, red shaded area on the left sideof the screen which would change to green with the hue control. 2) nocontrol of picture, volume control would cause picture to vary and at aset point on the volume setting the picture control
SONYKX2501
Shut down, replaced flybackUnit would shut down every one or two minutes after 2 hourswarm up. i could not find anything wrong, but read fdrs and noticedflyback could be cause.
SONYKX2501
Shutdown, replaced h stat blockH. v. shut down activates intermittently.