Brand | Model | Fault | Detailed Problem | Solution | By |
---|---|---|---|---|---|
AIWA | NSX-S22 | Don't read the CD for two rounds, play the laiser but don't read | Change the plate under the table and check the flats | Help yourself leave your tip | ELETRONICA ARNI-LEOBERTO LEAL /SC |
AIWA | NSX-S22 | C dl | Optical unit | Help yourself leave your tip | ELETRONICA ARNI-LEOBERTO LEAL /SC |
AIWA | NSX-S22 | There is no sound on the CD, just a low noise, and on the radio, aux and normal deck | Optical unit | ELETRONICA ARNI-LEOBERTO LEAL /SC | |
AIWA | NSX-S22 | There is no sound on the CD, just a low noise, and on the radio, aux and normal deck | Optical unit | ELETRONICA ARNI-LEOBERTO LEAL /SC | |
AIWA | NSX-S22 | There is no sound on the CD, just a low noise, and on the radio, aux and normal deck | Change the plate under the table and check the flats | ELETRONICA ARNI-LEOBERTO LEAL /SC | |
AIWA | F15 | Turns off by itself even without the box | Small pieces of wire break inside the box connector | Remove the connector and remove them, there are some that get stuck with the shorts | wendel |
AIWA | CX-NS505 - NSX-S505 | The display lights up normally, after a few minutes it starts to flash slowly and increases until it goes out and some characters randomly light up. | Q102 (rn1410) | I removed the transistor, as I didn't have another one to replace it, I left it without it, and the device is working perfectly, without any problems. All device functions are working. | Aderbal |
AIWA | NSX- S74 | Hoarse sound | Pr201 open | Adrian Chapadão | |
AIWA | NSX- S74 | Turns on and off at the same time | Cap 3300yf/75v da power supply e q219 | Replace | Adrian Chapadão |
AIWA | NSX-S22 | Turns on turns off only stays on standby when turned on turns off immediately | Pr 201 was just changing and running for the hug | CARLOS AUGUSTO ELETROSILVA CANAVIEIRAS BAHIA | |
AIWA | TV-AR295RH | RGB defects and only displays video when enlarging the screen | R904, r910, r916 (100k) | Check r904, r910, r916 (all 100k) | MACCELETRONICA |
AIWA | Z-R900 | Opt unit mechanics. inoperative and the tray does not rotate | Skip doesn't work and doesn't search for cds | Replace a 33hs\1w resistor on the board under the tray, position the optc unit in play with the larger pulley out, then just put the pulley in place and hug | ffeet |
AIWA | NSX-F958 | When turning on the box turns off immediately | R-268 open | ||
AIWA | TV-AR295 RH | Didn't care | Saida horizontal bu 4508 dx cap.826 100uf 160 v | vicena | |
AIWA | MOD:CX-Z1200 | CD: time it would play, it would fail and the drawer wouldn't move, I had to unplug it, put it back in, then the drawer would come out and the CD would play, when changing the CD it would also fail. | I changed the belt, I changed the optical unit, nothing solved it. In search of another cause, I found IC 603 with cold soldering on four terminals, I solved it and the defect was resolved. | Francisco Gonçalves | |
AIWA | CZ-NF959LH | Display off | PR107 fuse open on panel board | retec | |
AIWA | NSX-S32 | Turns off when the volume is increased, even without the speakers connected | A 214 with leak in the r channel can be replaced by 2n5551 | To find out which channel is defective, turn off the input signal at the c, so you can know if the problem is at the output and on which channel | BRUSKE |
AIWA | CSD EX180 | Does not turn on, only on standby | S620 vol up contact switch featuring a resistance of 5 megaΩ | Replace contact key | |
AIWA | NSZ-71 EQUIP.SOM | Does not come out of standby | Transistor q 101 smd with leakage | Replace the same (cmbt 5401) or similar pnp | neilson nicacio |
AIWA | NSZ-71 EQUIP. SOM | Doesn't start | CMBT 5401 transistor (SMD) with leakage | Replace the same | neilson nicácio |