GRUNDIG CUC2080
After replacment of fbt, the set starts and reverts to standby mode immediately. if the crt heater is fed by an external transformer i.e. 6 v. a/c, the screen will show a very weak light, except in the corners13v. was present on pin 11 of v. output ic tda8350q during the brief moment when the set tried to start. the tda8350q was found to be defective and was replaced. don't forget to check +a voltage after replacing the fbt
GRUNDIG M70-495 CUC-3800
Dead setI replaced the bu546 transistor in the power supply and resoldered some paths on the pcb. an intermittent soldering path to the collector of the transistor was the reason for the destroyed bu546
GRUNDIG ST82-774 TOP/EURO
Not starting, power supply working perfectly display presentReplaced the horizontal deflection power driver ic tda8140
GRUNDIG CUC6310
No east-westCheck r569, tda8145, d566
GRUNDIG T55-731 CUC7303 / FET TYPE
Dead bridge and chopper transistor s/cIf no d663 fitted this is version 2 has fet and uc3843. failure of p.s components caused by c669 dry jointed. check/change fet buz90, d667 ba157, r661 4.7k not 220r version 1, r666 and r667 56r 1w, r663 10r and the uc3843. all values for 20"
GRUNDIG M82-795 CUC7880
Dead, 800ma fuse blownCheck for dry joints on the chopper transformer also check d663, d664, d666, c653 4.7nf and c667 2.2uf
GRUNDIG CUC5350
Goes to standby after a short timeReplace c631 1uf, 63v
GRUNDIG VS920
No remote control operation or modulator outputUnlock the video with code 4934 + ok. check if you have the remote control set on video 1. when you have the rp 95 remote you can set the remote to video 1 with code 8527 + ok
GRUNDIG T55-640 CUC 6300
Sleep timer box on screen, remote & front buttons not workingChanged the eeprom ic847 24c04
GRUNDIG CUC5310
Picture int disappears leaving snow on screenResolder the xtal in the tuner
GRUNDIG M70-490/9 TEXT CUC3800
No sound, picture okWhen shifting up the channel frequency using the fine tuning, a very weak sound could be heard. replaced the sound if demodulator chip u2829bic2110
GRUNDIG CUC5310
Dead, no shorts foundLook for dry joints on the scan coil plug may not be visible also solder the 12v and 5v regs
GRUNDIG ST70-460 CUC4635
Intermittent start up and trippingDry joint on r636, vertically mounted 4.7Ω wirewound in sw mode circuit
GRUNDIG CUC7301/3
Power supply blownThis is often caused by a dry joint at c669 in the snubber network but also check the mains bridge rectifiers reservoir capacitor 47uf, 385v for o/c, this item is not included in the ususal p.s.u repair kits and if not checked may result in a repeat blow up !
GRUNDIG G1000
Tripping with burning smellLoptx
GRUNDIG G1000
St/by onlyNo line drive - r314 6k8 2w o/c
GRUNDIG G1000
Blank raster and narrowR315 10r o/c - supply to rgb stage also dry joints power trs
GRUNDIG CUC7350
Dead - mains fuse shatteredD60013/4 mains rects s/c, chopper fet t60020 irfbc40 s/c used buz90 uc3843 replaced as prec,caused by dry joints chopper tfmr
GRUNDIG CUC7350
Dead - +8v supply absentR61021 15r safety res in 8v reg o/c
GRUNDIG CUC7301/3
Mains fuse s1600 2.5a blows int1n4007 mains rect diode, also check ic630, t665chopper tr, zener d663, r661220r,caps c661/663/656 & 667