GRUNDIGG1000
To enter service modePress "p+" & "p-" together at sw on. to choose a funct select menu on r/c. adj with "p+" & "p-" buttons. choosing another funct stores setting
GRUNDIGG1000
St/by onlyD304 by133 s/c ; r314 6k8 4w o/c
GRUNDIGG1000
Reduced width with foldoverCheck line freq is not twice normal - if so micro ic500 75990-200-63 faulty - mod available
GRUNDIGG1000
Pink raster with striations sound/rc okChanged 6 trs on crt base + 3 15k resistors cured it
GRUNDIGG1000
Peak white pic with fb linesR999 100r on crt base
GRUNDIGG1000
No soundR550 4r7 (9v feed to audio chip) tda2822m ic550 o/c
GRUNDIGG1000
No lum in txtSm tr653 bc847 leaky b-e
GRUNDIGG1000
Int psu failure, grey scale variations etcCheck c104 47mfd 400v - if black siemens type replace it
GRUNDIGG1000
Instability using scart i/pMicro chip faulty
GRUNDIGG1000
Field collapseR337 100r
GRUNDIGG1000
Dead & tickingD301 ba157 26v supply s/c
GRUNDIGG1000
Dead - trippingD304 by133 in lop s/c
GRUNDIGG1000
Dead - slowly tickingC104 mains smoother o/c
GRUNDIGG1000
Dead - no 9v supplyR116 fusible o/c ic102 5v reg overheats - c543 sm cap under ยต s/c
GRUNDIGG1000
Dead - lop tr s/c & high ht (200v)D105 bas16 sm leaky
GRUNDIGG1000
Dead - ic500 st6365 micro not being resetNo reset pulse pin 33 due to either tr540 bc847 or tr451 bcx19 sm trs going s/c - replace both
GRUNDIGG1000
Bright raster sound okR316 10r in ht o/c also replaced rect & smoother to be safe
GRUNDIGG100
Bright white raster - sound okR315 100r 1/4w fusible o/c
GRUNDIGCUC95
No pic, heaters or eht - no line pulses from tda1950Eht cap had been arcing and caused demise of tb chip tda1950 & tda1770 field chip
GRUNDIGCUC95
Field collapseAll 3 field pre-set pots had been twiddled & broken - replacement cure