Search: GRUNDIG
Results: 948

GRUNDIG Repair Guide: Common Issues and Fixes

Brand Model Fault Detailed Problem Solution By
GRUNDIGGT2103
Hum barMains smoother 47µ 385v o/c
GRUNDIGGT1401
No sound or pic5v supply missing because d114 cathode no soldered thro' print
GRUNDIGGSC700
Int smeary flat picture.Luma delay line leaky.
GRUNDIGGSC200 CHASSIS
No sound or picture, led displays not lit.eht at 18kv.C2607 in relay pcb sced.check also d334 and d335 in tuning module as in one case they were found to be sced together with c2607.
GRUNDIGGSC200 CHASSIS
Black screen, eht at about 18 kvs.Change di511.
GRUNDIGGSC200 CHASSIS
Arcing in picture. reduced width with torn edges.The ho transformer has a built in fuse holder which houses a 50ma fuse. (connected in series with the high tension cable). replace the fuse and clean the contacts.
GRUNDIGGSC200
No results.R607 o/c , r621 o/c , if goes agn few hrs later di2502 4.7v
GRUNDIGGSC100
R607 - repeated resoldering of r607.Di2502 ( 4.7v ) zener.
GRUNDIGGSC100
No frame.Di447 ( 1n4007 ) and/or tda1170.
GRUNDIGGSC100
Line break up.C2502 (100uf, 16v) ​​on eht control rule build pcb.
GRUNDIGGSC100
If eht is very highCheck di508 is open
GRUNDIGGSC100
Frame - bottom foldover - cramping at top.R2522 ( 2.2k ) goes high.
GRUNDIGGSC100
Dead.Di511 or c2502 (100u f, 16v) ​​on eht control rule building pcb.
GRUNDIGGSC100
Dead.R607 o/c , faulty thyristors , insulation in line o/p stage.
GRUNDIGGSC100
Dead - blowing 3.15amp fuse.Eht cap jumping across to degaussing coil.
GRUNDIGGSC100
Dead - blowing 3.15 fuse - intermittently.Eht cap arcing.
GRUNDIGGRT550
Dead.T661 ( s668t ) faulty.
GRUNDIGGCS100
Dead - blowing fusible resistor.Insulating pad under ty501 leaky.
GRUNDIGG1000 GT2103
Bright raster with fb linesR315 10r near loptx o/c - supplies volts to rgb
GRUNDIGG1000
Unfocused 6 inch wide band down screen onlyLine freq twice operating freq - cannot be adj - ic500 micro faulty