GRUNDIGCUC95
Field collapseR2754 1m preset
GRUNDIGCUC95
Dead - bu208 s/c.R646 high.
GRUNDIGCUC7890
Focus poorC07 680pf 12kv leaky
GRUNDIGCUC7861
St/by only - started as line collapseR503 4r7 safety res, tda8350, d503 by228 s/c & t572 2sd1432 breaking down under load - also check d502, d438 33v zener
GRUNDIGCUC7861
Sound from bass speaker weakCt4140 bc849c sm tr o/c
GRUNDIGCUC7861
Poor field,no tuning, no col, smeary pic45v supply low due to r552 2r2 o/c
GRUNDIGCUC770
Line tearingCheck or change c501 ( 1000uf , 25v )
GRUNDIGCUC7530
No h drive(bc848) which is used as a line protector.
GRUNDIGCUC740
Sound couldn't be reduced &"88" in displayMc144111 ic2335 on tuning pcb
GRUNDIGCUC740
Pulling/rolling with weak syncReplace 2 x 1µ caps & 1 x 10µ cap in if module
GRUNDIGCUC740
Pulling/rolling - weak sync2 x 1µ & 1 10µ cap in if module
GRUNDIGCUC740
No adj of vol,col,contrast etcIc2335 mc144111 inside if/tuner can
GRUNDIGCUC740
Lines across screen - no soundAdj r2741 on deflection pcb
GRUNDIGCUC740
Int soundCheck if +g supply missing - if so check relay contacts
GRUNDIGCUC740
Int dead or int st/byC633 100µ 25v
GRUNDIGCUC740
Int deadD671 by299 in 5v supply int o/c
GRUNDIGCUC740
Int cutout , going to sby or deadD671 5v supply
GRUNDIGCUC740
Excess widthD572 ske4g2/06
GRUNDIGCUC740
Dead - s1644 1.25a fuse blownT654 bu208a s/c - check for arcing at c634
GRUNDIGCUC740
Dead - comes on briefly when tappedDry joints chopper tr and surroundings