Search: PHILIPS
Results: 14173

PHILIPS Repair Guide: Common Issues and Fixes

Brand Model Fault Detailed Problem Solution By
PHILIPSCP90
Int sound at switch onBad conns h.phone skt - linked out
PHILIPSCP90
Int pictureDry joints in if can
PHILIPSCP90
Int off when heatedPin 2 chopper tfmr t5654 dry joints
PHILIPSCP90
Int heightDry joints in fop stage & psu
PHILIPSCP90
Int flashing - low gain - poor sync.Drys in if/sync can.
PHILIPSCP90
Int fail to switch onC2700 4µ7
PHILIPSCP90
Int dead with whistle from chopperC2700 4.7uf o/c in the psu.
PHILIPSCP90
Impurity & lines at sw onDegaussing therm 98017 - used 96009 & dry joints loptx
PHILIPSCP90
Function knobs on ctv failVoltage + 4,9 v on pin 42 ic 7840 present. oscillogramm on pin 31,32 present. replace ic 7840 (tmp47c432p-8188; 4822 310 31849). important: mount the metal-shielding with earth to bridge 9732 (tmp47c432p-8189; 4822 310 31851)
PHILIPSCP90
From cold will come on if warm will not start upD6670 ( in4418 )
PHILIPSCP90
Frame collapse - with small scan below it.Crack in print by r3275.
PHILIPSCP90
Focus fluctuatesTr5763
PHILIPSCP90
Fluttering pic - ht normalC2638 470µ 16v in 13.5v supply or check elect caps in if can
PHILIPSCP90
Flasing/lines on pic when coldDry joints if module - esp the chips
PHILIPSCP90
Field scan very low ( 1/2 inch )Raakhdhi A. A. Ahm
PHILIPSCP90
Field collapse with bright line across screenR3623 8r2 in 163v supply o/c
PHILIPSCP90
Field collapse - small amount of scan belowNo 95v to fop stage - crack in print by r3275 or r3582 3r3 o/c
PHILIPSCP90
Field collapse 2. poor contrastR3623 8r2 oc 2. preset r3944 5k oc
PHILIPSCP90
Field collapseR3623 8r2 o/c in 163v line from loptx
PHILIPSCP90
Field collapseR3623 ( 8.2Ω ) 163v supply