Brand | Model | Fault | Detailed Problem | Solution | By |
---|---|---|---|---|---|
PHILIPS | CP110 | Txt - letter at far right of each page faulty | Upd4364 rom chip in txt cct | ||
PHILIPS | CP110 | Tuning - drift & flickering. | Replace d6673 ( byv95a ) | ||
PHILIPS | CP110 | Tries to start then shuts down | Tr7666 bc 337, tr7671 bc327-16, r3628 18r | ||
PHILIPS | CP110 | Text - flickering. | Replace d6673 ( byv95a ) | ||
PHILIPS | CP110 | Striations lhs | D6630 o/c | ||
PHILIPS | CP110 | Spare part information | Spare part information only for 25", ag..9047 and ag..9048 in a number of sets the darkglass crt has been replaced by a light crt. for service the darkglass can be used. it is recommended to add r3488 47k. | ||
PHILIPS | CP110 | Sound but no pic , eht and heaters ok. may be only | Cnx62a optocoupler causing excessive ripple on lt and ht lines | ||
PHILIPS | CP110 | Sometimes sound gets louder | Ic7840 (4822 209 72038 mask 8188 or 4822 209 73665 mask 8189). | ||
PHILIPS | CP110 | Sometimes no sound, no picture | Replace ic 7840 (tmp47c432ap-8188; 4822 310 31849) or (tmp47c432ap-8189; 4822 310 31851) important: mount the metal shielding with earth to r 3276 | ||
PHILIPS | CP110 | Set starts but as picture appears trips violently | Degaussing positor us | ||
PHILIPS | CP110 | Set pulses on and off gradually staying on longer | Try tea1039 and optocoupler if still faulty check 15v protection pcb near chopper tx and change 100uf capacitor | ||
PHILIPS | CP110 | Set intermittently tripping and/or reverting to channel 1. | Check all spark gaps on crt base. resolder aquadag lead to chassis. | ||
PHILIPS | CP110 | Servicing the cp110 chassis | See tv mag jun 1993 | ||
PHILIPS | CP110 | Scart o/p has no synch with lines/interference - ok on rf | Check for dry joints in psu, field & lop stages. caps 2075,2072 10u & 2073 33uf = 12v decoupling on sw ic | ||
PHILIPS | CP110 | Repeated failure of the supply | Mount a resistor in parallel to coil s 5656 (39Ω; 4822 050 23909). check/replace r3655 - 22Ω, and c2660 - 1uf at 250 volts, polyester type. check resistor r3660 - 0.1Ω (4822 113 80429). | ||
PHILIPS | CP110 | Reduced width | Check c2620 ( 22nf ) r3599 ( 47r ) r3629 ( 1m ) r3639 ( 47k ) | ||
PHILIPS | CP110 | R/c has low gain | C2967 100µ 10v in r/c receiver | ||
PHILIPS | CP110 | Pulsing in and out of sby untill warm | Check small subpanel for faults esp 100mfd | ||
PHILIPS | CP110 | Pulses in /out of st/by at sw on | 100µ cap on separate over volts prot panel for 15v supply | ||
PHILIPS | CP110 | Psu trips after rebuild | Tr7727 bd438 in opto coupler cct |