Brand Model Fault Detailed Problem Solution By
PHILCOPC2001
With tinnitusR701 open
PHILCOPAVM 2050
With sound without video, tuning and switching worksIc3005
PHILCOPCR1449
Works and then turns offZd941 (30v)
PHILCOCPH-05
Contrast control inoperativeR717(82k or 100k) with changed or open value
PHILCOCPH-05
Turns off for no apparent reason.R706(10k)
PHILCOCPH-05
No colorC212(100nf)
PHILCOCPH-05
Poor vertical deflection680k r601 changed
PHILCOPCS 2700
Saturated image with return lineR715 de 4,7Ω o c718 de 470pf e o d701
PHILCOPCS 2700
Image shaking verticallyC 723 of 2.2x 63 v
PHILCOPC2025
No image and sound. when it turns on it makes a noise and stops.Q903 bf42
PHILCOPC2004
Horizontal dark barC607 10uf-160v
PHILCOPC2004
Without vertical and horizontal synchronizationC701 820pf
PHILCOPCM 1444
Turning offC 706
PHILCOPCR- 2049
Audio chiandoC401 820pf
PHILCOPCR-1447
DeadC710 (33nf) e ou fly back
PHILCOPC2004
No image and soundC916 390pf-500v
PHILCOPVM2050
No image and no soundR712 4k7-3w open
PHILCOPCM 1444-2044-2144
Vertical closedR601 (680k)
PHILCOPCM 1444-2044-2144
Image coming and going (circ/ prot/ actuando)R713- 100k
PHILCOPC2043
Violet color screenC515 22n