TV Repair: Common Faults and Solutions.
Search:
Results: 87426
Results: 87426
Repair Guide: Common Issues and Fixes
Brand | Model | Fault | Detailed Problem | Solution | By |
---|---|---|---|---|---|
SONY | CCDV9 | No auto focus | No auto focus. manual focus slow and hunts. | ||
SONY | CDXR88 | No tuner operation | No am or fm. (no scan stop. manual tune gives no backgroundstatic, or audio at all). found no output from q17 its base was 0.57vdc. | ||
SONY | CCDM8SP | Vf jack part number | No p/n listed in manual. -hq comments: p/n is 1-562-183-00. | ||
SONY | KV2092R | Bottom half of picture distorted, c1504 | Top half of pix was fine, bottom half was stretched and dis-torted. scopes of pin 3 or 6 of ic1501 shows rf riding on b+. foundc1504 had changed value - replaced problem cured. | ||
SONY | FD42A | No pix, replaced q802, d802, ic601 and q602 | 1. no picture. 2. no high voltage. 3. bad keystone.1. weak drive signal on q801 base.2. open q802.3. no drive of pin 5 (ic601) open q602. | ||
SONY | CDP701ES | High frequency whistle in one channel | High freq. whistle in one channel. found cold solder joint onlpf ground tab. this problem could occur on lpf401 effecting other side. | ||
SONY | CDP203 | Wrong part | The part number for the main board is incorrect. | ||
SONY | SLHF1000 | One weak or no video head output | Original problem was one video head tip broken. replaced withnew disk assy then had symptom of dirty or clogged video heads unable toclear, changed head disk assy. same results, (bis worked fine) changedentire drum assy. same results, changed head swi | ||
SONY | KPR4110 | No picture and no sound, resoldered the flyback | No picture and no sound. | ||
SONY | SPP110 | Id code is not sent to handset | Id code not sent to handset. test mode showed no problems.when handset was placed on base unit, id code would not be sent to handset. | ||
SONY | ITK300 | Time indicator not working, only color marker | Only color marks on indicator tube are illuminated. checkingvoltages, found pin 14 of ic401 to be 13v. checked resistance across d401and reading was zeroΩ. further resistance checks found c401 shorted. | ||
SONY | MPKM8 | Part number for mic cable | The elusive mic cable p/n is now known, and are on order fromjapan. -hq comments: this p/n was given to us last year, but was unavailable atthat time. we have confirmed with tokyo that this part is now available.ten pieces will be sent to our departmen | ||
SONY | SLHF300 | No tuner, no channel display | All functions ok, except for the tuner being inoperative andno channel display. unit stuck in line mode. | ||
SONY | CCDV5 | Viewfinder crt | The original viewfinder is using a crt made by nec with gener-ic number on tube c1m40p45. the replacement tube part no. 1-546-061-11 aslisted in service manual is made by matsushita gen. no. m01jpg5wb (seeillustration): the tube in fig. 1 uses board no | ||
SONY | CCDV110 | Vertical smear from bright object | Have had two units come in for severe vertical smear frombright object. when camera is rotated, smear remains vertical. foundsmear caused by dt61. | ||
SONY | KV2780R | Poor vertical, replace r-1503 and adj rv-505 | Unit had poor vertical interface, very noticeable about 5 in-ches down from the top of screen. waveform at pin 2, ic-1501 displayeddistortion. found r-1503 to be open. replacement did not cure problembut i also had to readjust rv-505, vertical bias. | ||
SONY | KV2093R | Intermittent brightness shift, replace rv-707 sub brt | Complaint was intermittent shift 17 brightness level. al-though the sub-brightness control checked ok, replacement eliminated thecomplaint. this the third set of this type that i have had this problemwith this control. sometimes spraying coolant on th | ||
SONY | XR55 | Part number incorrect in service manual | The part numbers listed above are in xr-55 service manual ascorrect p/ns for switches in this unit. servicers called and statedswitches were different than what was in the unit. | ||
SONY | XR17 | No output | No output. found q307 shorted b-c (factory sub.). | ||
SONY | D10 | Intermittent starting and poor tracking | There is very dirty eyepattern. the servo pc board is dis-connected from chassis ground, the mounting screw is slightly loose. |