Brand | Model | Fault | Detailed Problem | Solution | By |
---|---|---|---|---|---|
SONY | UP811 | Unit will not print | Printed motor will not feed. no motion at all. | ||
SONY | CCDV110 | Defective chip resistor | Loose color on camera and no characters on viewfinder. | ||
SONY | CCDV110 | Defective chip cap | No picture on camera. | ||
SONY | CCDV110 | Viewfinder has dark pix | Viewfinder pix is weak and dark. looks like soft tube. | ||
SONY | KV20XBR | No main sound, leaky q1115 | When on main sound, no audio left or right. when switched tosap (with sap broadcast) sound ok. traced problem q1115, main audio up tobase, nothing on collector. found q1115 leaky emitter to collector. | ||
SONY | KV1956R | Noisy when power off, 15v reg q1002 open | Audio buzzing and popping while set is off, but still plugged to ac. | ||
SONY | KV25XBR | Erratic power on function | The unit would turn on after pushing power switch severaltimes manually or remote. found r653/r660 on ga board increased to1 megΩ. these are carbon resistors. | ||
SONY | CCDV1 | No time or date recording on tape | Unit would not record date or time information on tape. unitwould display date and time on ccd display and data indicator in view-finder would function normally. | ||
SONY | CFSDW60 | Wrong head | Please note enclosed samples, we need the correct rec/pb headfor deck a. the stocked part is incorrect. please advise. -hq comments: correct p/n is 1-543-406-11. we will issue a s/b. | ||
SONY | SL2410 | No capstan servo | The capstan servo on these units would not lock up. thecustomer tracking control pot was found to be open. the servo freq. wasclose but not locked. | ||
SONY | KV1981R | Shut down, replaced open q502 and shorted c553 | No picture, then unit shuts off. | ||
SONY | CDXA10 | Car stereo service bulletin #73 (cdxa10 disc pack) | Disc pack can be safely and easily removed in 5 secs followingmy procedure rather than following s/b #73 (car stereo). use a flatobject (i use a straightened stainless steel clasp senior - made in japan.this clasp can be obtained at any stationery store | ||
SONY | SLHF900 | Popping noise in hi-fi sound | Audio popping. s/b #210 improved problem, but did noteliminate it. -hq comments: have servicer confirm that resistor and cap wereincreased to max specified value. | ||
SONY | XR510R | No playback, no ams | No b+ to ic301. q329 was cold soldered (factory) on all legs. | ||
SONY | CCDV5 | Clogged heads | Distorted picture. | ||
SONY | STRAV780 | No stereo reception, searches but does not find stations | 1) manual tuning worked ok except for no stereo indicator.2) when performing search, indicator moved on spectrum display screen, butno station markers were placed on it. | ||
SONY | KV2075R | Weak sound, replace q1404 | Audio is weak on full volume. | ||
SONY | SLHF1000 | Tape path | Customer had bought 2 identical machines. could not playtape recorded on machine #1 or machine #2 and vice versa. picture wouldbreak-up. | ||
SONY | DT3 | The turntable does not spin | 8.6v appear at the collector of q401 when only 4.5v should bepresent. q401 is found to be shorted. many dt-3 or d3 units have thesame problem. | ||
SONY | SL2000 | Substitute pinch roller | When this new substitute part pinch roller x-3669-307-6 isinstalled, the adjustment of the pinch closing limitter (step 3-11 page3-11) cannot be made to fall within the spec. this will cause a veryintermittent jamming of the pinch roller. |