Repair Guide: Common Issues and Fixes

Brand Model Fault Detailed Problem Solution By
SONYSL2400
Negative picture during c/rDuring cue, rev or pause the unit would intermittently producea negative like picture, we found delay line dl-1 to be open.
SONYKV2680R
No pix, no sound, leaky c-104 replacedUnit when turned on would come up with high voltage but nosound, no picture and no control from front panel of any function. foundc104 reading 150Ω on pin 15 of ic105. this capacitor caused no mclock on pin 25 of ic103.
SONYCFS5000
Wrong p/nNo such part number (a-3247-124-a) and cfs-5000 has 2 colors. holder, cassette (gray) x-3321-505-1 holder, cassette (gold) x-3321-505-2 -hq comments: we will issue a s/b.
SONYD5
No powerUnit had no power.
SONYCCDV8
No e to eNo blanking.
SONYCCDV8
No ejectNo mode power dc.
SONYCCDV8
Beta scan noiseBeta scan damaged tape.
SONYTV520
Different pinoutSubstitute picture tube has different pinout than originalone. kc says that this is a good sub but a bulletin was issued on howto rewire set, i can find no record of it. -hq comments: we will investigate this problem and if necessary, issuea t/n and s/
SONYSPP11
Noise in handsetHand set would make all kind of noises. when power was firstturned on, it would dial one digit.
SONYSL10
Noisy special effects in beta iiBeta ii pause, betascan and beta skipscan is noisy anddifficult to watch. -hq comments: this is normal operation for the sl-10 in beta ii opera-tion. this model does not have the required 1/2h delay line or the jogprocess ic which is used for error fre
SONYCFS5000
Incorrect p/n - band select switchPart number ordered is also stamped on part received. partordered is two position switch approx. 1 1/2 inches long with 8 pins inmiddle, part received is approx. 2 inches long with 16 pins along entirelength. we think part number in the manual is wrong
SONYCCDV8
Drum was not startingDrum was not starting.
SONYCDP200
Chucking arm ass'yChucking arm seems to be the biggest problem on this model.can the arm assembly be updated to the magnet type used in cdp-302? fscshave chronic complaints and no positive solution. -hq comments: the cdp-200 has no magnetic type arm assy. to correct th
SONYCDP70
No sled operationSled motor would not run.
SONYCDP520ES
Skips backwards near end of diskOn last selection, sled jumps backwards.
SONYSL2500
Full erase head on at all timesNo playback except for the first few sec. counter works for5 sec then stops as picture disappears. found no video/audio or ctl afterrewinding and tried to play it. power was already on and erasing tape.
SONYWM16
Audio is distorted - tape speed too fastMotor control board cracks when bottom case is put on unit.this causes motor to run too fast.
SONYSL2710
Clogged headRepetitive clogging, then one head dead.
SONYCFS950
Problem with cassette loadingA sony lnx90 cassette would not load properly. the tape wouldblock the head and pinch roller from engaging.
SONYSPP22
Cannot talk outAll functions were normal except talking from hand unit, the other person could not hear.