Search:
Results: 87416

Repair Guide: Common Issues and Fixes

Brand Model Fault Detailed Problem Solution By
SONYKV1510
Part's compatibilityWhen subbing the 1-463-109-00 tuner with the 1-463-132-00,the channel indicator numbers go down when they should go up and viceversa. -hq comments: replace the original tuner. in addition you have to orderdial drums from kv-1511: s/m page 32, p/n 4-31
SONYKV1205
Intermittent shut down, replaced q509Found q509 (hv protect) breaking down. replaced q509.
SONYFD210
No picture, resoldered c653This unit had no picture and received fm stations instead oftv freq. a quick examination of the power supply revealed that the 14vand 40v (tuning) lines were very low (6v). we found the connection onc653 to be poor. this is the coupling capacitor betw
SONYVTX1000
No tuning operationWould not tune any channels. vc voltage to tuner remainedhigh. no pulses out of the ic001.
SONYKX2501
Intermittent shut down, replaced hv blockIntermittent hv shutdown.
SONYKX2501
No picture, replaced ic1201. r668, and r676This unit had a washed out picture with no control of pictureor volume. also unit had no audio out.
SONYKV2654R
Shut down, replace q501 and q502If set was turned on with 120vac, horiz. output would shortout within 2 to 3 seconds. removing collector b+ off horizontal outputi was able to bring set up to 120vac and observe the driver output. foundwaveform to be distorted, should look like a squar
SONYKV2649RX
Bad reception on cableIf the cable signal coming into the distribution amplifierbeing used by the dealer is disconnected and reconnected, the channels onthe kv-2649rx come back extremely detuned, and can only be received if youaccess another channel and the set is ok. -hq co
SONYKV2649R
No power and tuning operation, shorted d021 on mt boardUnit could not be powered off nor any channels changed,display locked on channel 11, reception was normal.
SONYKV2648R
Buzz in audio, adj aft and sound ifBuzz on some channels in audio.
SONYKV2647R
Jail bars on the screenThis unit had very faint jail bars on the left side ofpicture. d250 zener voltage - 13.21 volts. 12 volt line - 12.61 volts.
SONYKV2644R
Intermittent time display, replaced neon tube nd3051Time indicator display would go out intermittently. found bytapping the neon tube when the set was cold, i could cause the problem tohappen. but after the set warmed up, could not produce the problem.
SONYKV2643R
Jail bars on the screen, replaced c539This unit had jail bars across the screen.
SONYKV1954R
No turn off, replace ic001Dealer noticed he could not turn off the set, which was ondisplay. none of the other functions worked either. after discussingwith the dealer i suspect failure was caused by static electricity.
SONYKV1954R
No audio, replace reg ic601Not audio.
SONYKV1953RS
Bad reception, replace band sw ic002This unit did not have the proper band switching voltages.we found the input to ic002 correct but the output was incorrect.
SONYKV1952RS
Picture distortion, replace ic003The frequency would change intermittently. you could freezeic005 on my board and then it would look up. pin 4 of ic003 on my board has an incorrect voltage.
SONYKV1952RS
Snowy picture, c537 shortedSnowy picture on all channels. worse on low band. found-30v line to be missing, i.e. 0v.
SONYKV1952RS
Snowy picture, replace ic005Snowy picture. no vc. this unit had output from the localoscillator but was not being divided down in the prescaler. there was nooutput at tp61. we found ic005 - prescaler/pll ic to be defective.
SONYKV1952R
Dead, d601 openNo b+ regulation. found one rectifier in d601 opened (noresistance reading).